Supported Variables from the RFC 1213 MIB Appendix D
RADWIN 2000 User Manual Release 2.6.40 D-19
winlink1000OduPerfMonTdmIntervalEntry N/A This is an entry in the Interval Table. INDEX
{ifIndex winlink1000OduPerfMonTdmIntervalIdx }
winlink1000OduPerfMonTdmIntervalIdx RO This table is indexed per interval number. Each
interval is of 15 minutes and the oldest is 96.
winlink1000OduPerfMonTdmIntervalActiveSec
onds
RO Parameter indicating whether the TDM service
was active. Under TDM backup link the
parameter indicates whether the backup link was
active.
winlink1000OduPerfMonTdmDayTable N/A This table defines/keeps the TDM counters of the
last month (in resolution of days).
winlink1000OduPerfMonTdmDayEntry N/A This is an entry in the Days Table. INDEX {ifIndex
winlink1000OduPerfMonTdmDayIdx }
winlink1000OduPerfMonTdmDayIdx RO This table is indexed per Day number. Each
interval is of 15 minutes and the oldest is 96.
winlink1000OduPerfMonTdmDayActiveSecond
s
RO Parameter indicating whether the TDM service
was active. Under TDM backup link the
parameter indicates whether the backup link was
active.
winlink1000OduPerfMonTxThresh1 1.3.6.1.4.1.4458.1000.1.6.20 Integer RW When the Transmit power exceeds this threshold
a performance monitoring TSL1 counter is
incremented.
winlink1000OduPerfMonRxThresh1 1.3.6.1.4.1.4458.1000.1.6.21 Integer RW When the RX power exceeds this threshold a
performance monitoring RSL1 counter is
incremented.
winlink1000OduPerfMonRxThresh2 1.3.6.1.4.1.4458.1000.1.6.22 Integer RW When the RX power exceeds this threshold a
performance monitoring RSL2 counter is
incremented.
winlink1000OduPerfMonBBERThresh1 1.3.6.1.4.1.4458.1000.1.6.23 Integer RW When the BBER exceeds this threshold a
performance monitoring BBER counter is
incremented. The units are 1/10 of a percent.
winlink1000OduPerfMonEthCapacityThreshKb
ps
1.3.6.1.4.1.4458.1000.1.6.24 Integer RW When the current throughput is below this
threshold the corresponding counter is
incremented
winlink1000OduPerfMonHighTrafficThreshKbp
s
1.3.6.1.4.1.4458.1000.1.6.25 Integer RW When the current traffic is above this threshold
then corresponding counter is incremented.
winlink1000OduAgnGenAddTrapExt 1.3.6.1.4.1.4458.1000.1.7.1.1 Integer RW If 'yes' is chosen the ifIndex Unit Severity
Time_T and Alarm Id from the
winlink1000OduAgnCurrAlarmTable will be bind
to the end of each private trap.
winlink1000OduAgnGenSetMode 1.3.6.1.4.1.4458.1000.1.7.1.2 Integer RW This parameter is reserved to the element
manager provided with the product.
winlink1000OduAgnNTPCfgTimeServerIP 1.3.6.1.4.1.4458.1000.1.7.2.1 IpAddress RW IP address of the server from which the current
time is loaded.
winlink1000OduAgnNTPCfgTimeOffsetFromU
TC
1.3.6.1.4.1.4458.1000.1.7.2.2 Integer RW Offset from Coordinated Universal Time (minutes).
Possible values: -1440..1440.
winlink1000OduAgnRealTimeAndDate 1.3.6.1.4.1.4458.1000.1.7.2.3 OctetString RW This parameter specifies the real time and date
Format 'YYYY-MM-DD HH:MM:SS'
(Hexadecimal). A date-time specification:
field octets contents range ----- --
---- -------- ----- 1 1-2 year
0..65536 2 3 month 1..12
3 4 day 1..31 4 5 hour
0..23 5 6 minutes 0..59 6
7 seconds 0..60 (use 60
for leap-second) 7 8 deci-seconds
0..9 For example Tuesday May 26 1992
at 1:30:15 PM EDT would be displayed as: 07
c8 05 1a 0d 1e 0f 00 ( 1992 -5 -26 13:30:15 )
Table D-2: Private MIB Parameters (Sheet 14 of 24)
Name OID Type
Access
Description