Supported Variables from the RFC 1213 MIB Appendix D
RADWIN 2000 User Manual Release 2.6.40 D-26
winlink1000HbsAirLinkHsuRssBal RO Holds the RSS Balance of specific link (HSU side).
winlink1000HbsAirLinkHsuSerial RO Holds the serial number for specific HSU.
winlink1000HbsAirLinkTxOperMode RO Holds the TX operation mode.
winlink1000HbsAirHsuInBytes RO Number of frames received in the HSU Lan port.
winlink1000HbsAirHsuOutBytes RO Number of frames transmitted from the HSU Lan
port.
winlink1000HbsAirHsuInFrames RO Number of bytes received in the HSU Lan port.
winlink1000HbsAirHsuOutFrames RO Number of bytes transmitted from the HSU Lan
port.
winlink1000HbsAirHsuMacAddress RO HSU MAC Address.
winlink1000HbsAirMaxTputDown RO Max Throughput Downlink.
winlink1000HbsAirMaxTputUp RO Max Throughput Uplink.
winlink1000HbsAirLinkCompressedMon RO Holds all the link information in compressed binary
(Bytes/octets). Fields included (size in bytes):
Link State(1) Link Working Mode(1)
Session Id(4) HBS Est. Tput(4) HSU
Est. Tput(4) HBS Rss(1) HBS Rss
Balance(1) HSU Rss(1) HSU Rss
Balance(1) Tx Operation Mode(1)
HSU In Bytes(4) HSU Out Bytes(4)
HSU In Frames(4) HSU Out Frames(4)
HSU ID (1 bytes) HSU Rx Rate In Kbps (4) HSU
Tx Rate In Kbps (4) HSU Rx Rate In Fps (4)
HSU Tx Rate In Fps (4).
winlink1000HbsAirLinkCompressedStatic RO Holds all the configuration data of this link in
compressed format. Helps the NMS to get info
regarding new Unregistered links. Fields
Included: SessionID (4 bytes) HSU IP address
(4 bytes) HSU Name (32 bytes) HSU Location
(32 bytes) HSU Serial number (16 bytes) HSU
MAC Address (12 bytes) Air Link Range Max
Throughput Down (4 bytes) Max Throughput Up.
(4 bytes) Cpacity Limit (4 bytes) HSU Antenna
type (1 byte)
winlink1000HbsAirCpeCapacityLimit RO Capacity Limit in Kilo bit per second.
winlink1000HbsAirLinkAntennaType RO HSU External Antenna Type: Monopolar or
Bipolar.
winlink1000HbsAirHsuRxRateInKbps RO HSU Rx Rate in Kbps.
winlink1000HbsAirHsuTxRateInKbps RO HSU Tx Rate in Kbps.
winlink1000HbsAirHsuRxRateInFps RO HSU Tx Rate in Fps.
winlink1000HbsAirHsuTxRateInFps RO HSU Tx Rate in Fps.
winlink1000HbsAirComboSwitchSectorFreqBa
ndId
RW Switch Frequency band for the whole sector.
winlink1000HbsBridgeAgingTime RW Timeout in seconds for aging.
winlink1000HbsBridgeVlanTable N/A Holds the bridge Vlan operations towards all the
registered HSUs.
winlink1000HbsBridgeVlanEntry N/A HBS bridge Vlan table entry. INDEX {
winlink1000HbsBridgeVlanIndex }
winlink1000HbsBridgeVlanIndex RO HBS bridge Vlan table index.
winlink1000HbsBridgeVlanIngress RW HBS bridge Vlan ingress.
winlink1000HbsBridgeVlanEgress RW HBS bridge Vlan egress.
winlink1000HbsBridgeVlanFilterIn RW HBS bridge Vlan filter in.
winlink1000HbsBridgeVlanFilterOut RW HBS bridge Vlan filter out.
winlink1000HbsBridgeVlanDoubleTag RW HBS bridge Vlan double tag.
Table D-2: Private MIB Parameters (Sheet 21 of 24)
Name OID Type
Access