Supported Variables from the RFC 1213 MIB Appendix D
RADWIN 2000 User Manual Release 2.6.40 D-28
winlink1000HbsServiceQoSConfDownQueWei
ght
RW Weight in percent for each QoS group of the
Downlink direction (4 values separated by
comma).
winlink1000HbsPerfMonThreshTable N/A Holds the performance monitor thresholds towards
all the registered HSUs.
winlink1000HbsPerfMonThreshEntry N/A HBS performance monitor threshold table entry.
INDEX { winlink1000HbsPerfMonThreshIndex }
winlink1000HbsPerfMonThreshIndex RO HBS performance monitor threshold table index.
winlink1000HbsPerfMonTxThresh1 RW HBS performance monitor transmit power
threshold.
winlink1000HbsPerfMonRxThresh1 RW HBS performance monitor receive power threshold
1.
winlink1000HbsPerfMonRxThresh2 RW HBS performance monitor receive power threshold
2.
winlink1000HbsPerfMonBBERThresh1 RW HBS performance monitor BBER threshold.
winlink1000HbsPerfMonEstThroughputThresh
Kbps
RW HBS performance monitor estimated throughput
Threshold.
winlink1000HbsPerfMonHighTrafficThreshKbp
s
RW HBS performance monitor high traffic threshold.
winlink1000HbsPerfMonAirGenCurrTable N/A This table defines/keeps the ethernet counters of
the current 15 min interval.
winlink1000HbsPerfMonAirGenCurrEntry N/A This is an entry in the Current Interval Table.
INDEX {ifIndex }
winlink1000HbsPerfMonAirGenCurrRxMBytes RO Current RX Mega Bytes starting from the present
15 minutes period.
winlink1000HbsPerfMonAirGenCurrTxMBytes RO Current Transmit Mega Bytes starting from the
present 15 minutes period.
winlink1000HbsPerfMonAirGenCurrEthCapacit
yThreshUnder
RO The number of times throughput was below
threshold in the present 15 minutes period.
Relevant for point to point systems.
winlink1000HbsPerfMonAirGenCurrHighTraffic
ThreshExceed
RO The number of times actual traffic was above
threshold in the present 15 minutes period.
winlink1000HbsPerfMonAirGenCurrActiveSeco
nds
RO The number of seconds in which RPL Ethernet
swervice was not blocked in the present 15
minutes period.
winlink1000HbsPerfMonAirGenIntervalTable N/A This table defines/keeps the ethernet counters of
the last day (in resolution of 15 min intervals).
winlink1000HbsPerfMonAirGenIntervalEntry N/A This is an entry in the Interval Table. INDEX
{ifIndex winlink1000HbsPerfMonAirGenIntervalIdx
}
winlink1000HbsPerfMonAirGenIntervalIdx RO This table is indexed per interval number. Each
interval is of 15 minutes and the oldest is 96.
winlink1000HbsPerfMonAirGenIntervalRxMByt
es
RO Current RX Mega Bytes per interval.
winlink1000HbsPerfMonAirGenIntervalTxMByt
es
RO Current Transmit Mega Bytes per interval.
winlink1000HbsPerfMonAirGenIntervalEthCap
acityThreshUnder
RO The number of times throughput was below
threshold in the each interval. Relevant for point
to point systems.
winlink1000HbsPerfMonAirGenIntervalHighTra
fficThreshExceed
RO The number of times actual traffic was above
threshold in the each interval.
winlink1000HbsPerfMonAirGenIntervalActiveS
econds
RO The number of seconds in which RPL Ethernet
service was not blocked in the each interval.
winlink1000HbsPerfMonAirGenDayTable N/A This table defines/keeps the ethernet counters of
the last month (in resolution of days).
Table D-2: Private MIB Parameters (Sheet 23 of 24)
Name OID Type
Access
Description