Rain Master Irrigation Systems DX2 User Manual
Appendix A: Flow Meters Page 247
This problem cannot be cleared from the report until the water
limit is set to a higher value or until a new month begins.
Multiple Stations with Non-Overlap Protection
The Evolution DX2 controller allows the user the capability of
turning "on" several stations simultaneously. When flow meters
are used in this environment, the individual station limits are
summed and compared to the total flow rate. Therefore, you
must set up limits for each station to insure that flow limit checks
are performed properly.
Example:
Assume the upper limit for station 1 is 80 GPM and the
upper limit for station 2 is 50 GPM. If both stations are
on, the controller adds these limits. A problem is
reported if the flow exceeds the total of 130 GPM (80
GPM + 50 GPM).