Periodic System Maintenance
Testing Your Water
If you are relying on this system for nitrate reduction, we recommend
testing your water periodically (2 times a year minimum) with a
nitrate test kit (supplied) to ensure that the system is performing
properly. Additional nitrate test kits (part number 12061) can be
purchased from your local RainSoft Dealer.
If you are relying on this system for VOC reduction, we recommend
testing your water periodically (2 times a year minimum) to ensure
that the system is performing properly. Your local RainSoft Dealer
can arrange this testing for a nominal fee.
If you are relying on this system for cyst reduction, we recommend
testing your water periodically (2 times a year minimum) to ensure
that the system is performing properly. Your local RainSoft Dealer
can arrange this testing for a nominal fee.
If you are relying on this system for any other health claims, please
refer to the performance data sheets on pages 12
_
15. See your local
RainSoft Dealer for additional information.
For Wisconsin Residents Only: The State of Wisconsin requires that
your water be tested 2 times a year minimum for total dissolved solids
(to ensure that the system is performing properly). Your local RainSoft
Dealer can arrange this testing for a nominal fee.
System Components
Pre-filter
The pre-filter (see figure 5) removes particles and sediment as small as
5 microns in size from the water supply. The pre-filter requires
periodic replacement every 6 to 12 months after installation. Your
water quality and water usage may affect this replacement schedule.
Please refer to the chart on page 8 for replacement part numbers.
Membrane Cartridge
The membrane cartridge (see figure 5) is a spiral wound, semi-
permeable cartridge that requires periodic replacement approximately
every 18 months after installation. Your water quality and water usage
may affect this replacement schedule. Please refer to the chart on page
8 for replacement part numbers.
Post-filter
The post-filter (see figure 5) will remove unwanted tastes and odors
from the water. The post-filter requires periodic replacement every 6
to 12 months after installation. Your water quality and water usage
may affect this replacement schedule. Please refer to the chart on page
8 for replacement part numbers.
INLET
OUTLET
DRAIN OUTLET
STORAGE TANK
TANK PORT
SHUT OFF VALVE
PRE-FILTER
MEMBRANE
POST FILTER
Figure 5
!
Important Notes: Nitrate reduction units are
acceptable for treatment of influent concentra-
tions of no more than 27 ppm nitrate and 3 ppm
nitrite in combination (measures as “N”) and are
certified for nitrate/nitrite reduction only for
water supplies with a pressure of 40 psi or
greater.