Derating is a precaution to account for varying characteristics in the lighting loads; this can
include inrush currents and higher ambient temperatures, as well as recommendations from
3rd party lighting manufacturers.
Installation
Installation should only be carried out by a competent electrician.
● RMT500 modules should be mounted in areas that are adequately ventilated, dry,
and outside of any enclosed metal casings that may interfere with the wireless
signal.
● Modules should be mounted vertically, with the terminals at the bottom, or
horizontally.
● While the modules are designed to be maintenance-free, they should be mounted
in an accessible location should investigation or re-addressing of the units be
necessary.
● Ensure that the cable clamp is fitted tightly to secure the cables.
Remove the cover and
cable clamp
Insert the supply IN
conductors as well as the
load OUT conductors.
Replace the cable clamp,
ensuring the cables fit
securely underneath
RMT-500 Manual Version 2.0.0