This manual provides information on installation, operating,
maintenance, trouble shooting & replacement parts for:
OPERATOR MANUAL
IMPORTANT INFORMATION, KEEP FOR OPERATOR
PART NUMBER PP MNL1602, REV C (04/17)
RANSPEC
REFRIGERATORS:
51000 Series
53000 Series
Information contained in this document is known to be current and accurate at the time
of printing/creation. Unified Brands recommends referencing our product line websites,
unifiedbrands.net, for the most updated product information and specifications.
1055 Mendell Davis Drive
Jackson, MS 39272
888-994-7636, fax 888-864-7636
unifiedbrands.net
THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE.
READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND
WARNINGS CONTAINED IN THIS MANUAL.
WARNING / FOR YOUR SAFETY
Do not store or use gasoline or other ammable vapors
and liquids in the vicinity of this or any other appliance.
WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, injury or
death. Read the installation, operating and maintenance
instructions thoroughly before installing or servicing this
equipment.
NOTIFY CARRIER OF DAMAGE AT ONCE
It is the responsibility of the consignee to inspect the container upon receipt of
same and to determine the possibility of any damage, including concealed dam-
age. Unied Brands suggests that if you are suspicious of damage to make a
notation on the delivery receipt. It will be the responsibility of the consignee to le
a claim with the carrier. We recommend that you do so at once.
Manufacture Service/Questions 888-994-7636.

Questions and Answers

  • K
    Kristie DayJul 31, 2025
    How to troubleshoot a Randell 51000 that does not run?
    • A
      Alexis CampbellJul 31, 2025
      If your Randell Refrigerator unit isn't running, try these steps: First, ensure the unit is properly plugged in. If it is, check the temperature control settings and test the temperature control. Also, clean the condenser coil and service the condenser fan. If problems persist, test the overload and relay.
  • S
    ssheltonAug 4, 2025
    What to do if my Randell Refrigerator is not cold enough?
    • G
      Glenn MaloneAug 5, 2025
      To address a Randell Refrigerator that isn't cold enough, start by adjusting the control to a lower setting and testing the control. Additionally, make sure to clean the coil.
  • K
    Katie BowmanAug 8, 2025
    Why does my Randell Refrigerator run constantly?
    • M
      mathismichaelAug 9, 2025
      To fix a Randell Refrigerator that runs constantly, try cleaning the coil and servicing the condenser motor.
  • P
    Patrick GarciaAug 13, 2025
    What causes a Randell Refrigerator to short cycle?
    • J
      Jessica JonesAug 13, 2025
      To resolve short cycling in your Randell Refrigerator, clean the coil, service the fan and motor, and check the outlet voltage.
  • A
    Amanda HernandezAug 17, 2025
    What to do if my Randell 51000 is too cold?
    • J
      Jessica WoodAug 17, 2025
      If your Randell Refrigerator is too cold, adjust the control to raise the setting and test the control.
  • X
    xcampbellAug 21, 2025
    How to fix moisture around the door of my Randell 51000?
    • J
      Jack RobersonAug 22, 2025
      To address moisture around the door or frame of your Randell Refrigerator, inspect the strips and adjust the control to raise the setting.
  • D
    Diana FordAug 27, 2025
    How do I fix ice in the drain pan of my Randell 51000?
    • J
      James CrossAug 27, 2025
      To resolve ice in the drain pan or water at the bottom of your Randell Refrigerator, or on the floor, clean the drain and adjust the leveling feet.

Summary

Warranty Policies

Items Not Covered Under Warranty

Installation

Installation Checklist

Steps to follow before start-up: checking lines, fans, leveling, power, and temperature stabilization.

Operation

Maintenance

Monthly Maintenance Procedures

Covers cleaning condenser coils, fan blades, drain lines, gaskets, hinges, and inspecting silicone seams.

Troubleshooting

Unit Not Running or Short Cycling

Diagnoses causes and procedures for units that do not run or cycle on and off frequently.

Temperature and Noise Issues

Addresses problems like unit not cold enough, too cold, noisy operation, and drawer issues.

Moisture and Ice Problems

Troubleshoots moisture around doors/frames and ice buildup in drain pans or unit bottom.

Cleaning Condenser Coil and Drain

Instructions for cleaning the condenser coil and the drain system to maintain performance.

Servicing the Condenser Fan

Steps for inspecting, testing, and replacing the condenser fan motor and blade.

Servicing the Compressor Components

Guide to testing compressor relay, overload protector, and the compressor itself for faults.

Parts List - Door Components

Parts List - Compressors and Fans

Parts List - Shelving and Evaporator Coils

Evaporator Coil Assemblies

Lists part numbers for evaporator coil assemblies with and without controls, by manufacturing date.

Parts List - Evaporator System Components

Electrical Schematic - Standard Models

Electrical Schematic - Specific Models (51386, 51395)

Electrical Schematic - Pass Thru Models

Randell 51000 Series Specifications

General IconGeneral
BrandRandell
Series51000 Series
CategoryRefrigerator
CapacityVaries by model (check specific model for details)
Door TypeSolid or Glass
ShelvingAdjustable wire shelves
Energy EfficiencyEnergy Star certified models available
DimensionsVaries by model (check specific model for details)
WeightVaries by model (check specific model for details)

Related product manuals