Unit Operation (cont.)
To raise temperature in the refrigerated rail:
A. Push and hold the “set” button until 34 appears then release the “set”
button. 34 is the current set point temperature.
B. Push and release the up arrow 2 times until 36 is displayed. Push and
release the set” button one time. The new set point, 36, will flash 3
times and then will be locked in.
To lower temperature in the refrigerated rail:
A. Push and hold the set” button until 34 appears and then release the
“set” button. 34 is the current set point temperature.
B. Push and release the up arrow 2 times until 32 is displayed. Push and
release the set” button one time. The new set point, 32, will flash 3
times and then will be locked in.
NOTE: It is recommended to only make changes of 2 degree increments
at a time. Allow for the unit to operate 24 hours between adjustments. If
the 2 degree adjustment is not enough another adjustment can be made.
The maximum highest setting is 38 degrees and the minimum lowest
setting is 28 degrees. If the settings need to go above or below this point
there may be other contributing factors as to the cause of the
temperature variances, please contact the factory at 1-800-621-8560.
The base temperature can also be adjusted by the temperature control dial located
on the front of the refrigeration coil inside the refrigerated base. The thermometer
for the base temperature is located in the mechanical housing (Figure 1, item b).
To adjust temperature in the refrigerated base:
A. Locate evaporator coil inside cooler between the mechanical housing
and the refrigerated base cabinet.
B. Thermostat is located at top front of evaporator coil. There are numbers
to indicate settings.
C. Turn clockwise for colder setting (higher number).
D. Turn counterclockwise for warmer setting (lower number).
NOTE: It is not recommended to turn the dial above 8 or below 1 on the
temperature control. If the adjustments still do not result in proper
temperature please contact the factory at 1-800-621-8560.