EasyManuals Logo

Randell PH120E2 User Manual

Randell PH120E2
25 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #13 background imageLoading...
Page #13 background image
unifiedbrands.net 13
Preventive Maintenance
Randell strongly suggests a preventive maintenance program which would include
the following Monthly procedures:
1. Cleaning of all condenser coils. Condenser coils are a critical component in the
life of the compressor and must remain clean to assure proper air flow and heat
transfer. Failure to maintain this heat transfer will affect unit performance and
eventually destroy the compressor. Clean the condenser coils with coil cleaner
and/or a vacuum, cleaner and brush.
NOTE: Brush coil in direction of fins, normally vertically as to not damage or
restrict air from passing through condenser.
2. Clean fan blade on the condensing unit.
3. Clean and disinfect drains with a solution of warm water and mild soap.
4. Clean and disinfect drain lines and evaporator pan with a solution of warm water
and mild soap. Disconnect each end of the drain line and run the solution through
it. Do not allow the bleach water to be put into the condensate pan in the
compressor compartment.
5. Clean all gaskets on a weekly if not daily basis with a solution of warm water
and a mild detergent to extend gasket life.
NOTE: DO NOT USE SHARP UTENSILS.
NOTE: Do not pressure wash equipment as damage to electrical
components may result.