Translation of the original operation manual GB, Stand 02 / 2019
n OP 90 D 35/1 # 20 001
n OP 90 D 30/1 # 20 002
n OP 90 D 25/1 # 20 003
OP90D 35/1 OP90D 30/1
OP90D 25/1
i
Weiterentwicklung im Sinne des Fortschrittes behalten wir uns vor. - Technical Modifications are subject to change. - Details techniques subject à modification sans avis préalable
O P T I M I Z E S W O R K R O U T I N E S E N V I R O N M E N T A L L Y E F F E C T I V E S E C U R E

Questions and Answers

Summary

Safety Instructions

General Advice

Air Stopcock Usage

Close air stopcock during pauses/shutdowns to prevent unintentional supply from leaks.

Oil Installation Regulations

Only licensed companies can work on oil installations according to German law.

Permanent Oil Pipe Line Safety

Permanent oil pipe lines require a relief valve and a reflux hose to the storage container.

Explosion and Fire Hazards

Avoid operating the device in areas with explosion danger or near open fire.

Medium Compatibility

Device is not suitable for flammable mediums like R10, R11, R12 or dangerous class Al, AII, B.

Technical Data

Description

Type;1

Type /1: Oil pump with rigid suction pipe for barrel mounting.

Type;1 K

Type /1 "K": Stubby pump with flexible suction tube for wall mounting.

Type;1;E

Type /1 "/E": Calibratable version with air separator.

Assembling; Installation

Pump Preparation

Unwrap pump, remove caps, and seal suction pipe thread with Teflon stripe.

Suction Pipe Insertion

Insert pump suction pipe into barrel bunghole, fix with adapter. For stubby version, mount bracket and fix pump.

Oil Delivery Hose Connection

Screw oil delivery hose to outlet. For pipe line connection, use flexible hose model ÖSV.

Pipe Line Connection

Connect to pipe line with relief valve ÜSV 16 and insert reflux hose to storage container.

Air Connection Setup

Set up flexible air connection with block capability. Use maintenance unit with filter, oiler, pressure reducer.

Spare Parts and Accessories

Operation

Air Line Valve

Open the blocking valve on the air line to start operation.

Start Oil Supply

Open oil pistol or meter to start pump and oil supply.

Stop Oil Supply

Close oil pistol or meter to stop pump operation.

Operation Location

Do not operate pump in areas of explosion danger or near open fire.

Permitted Fluids

Pump only fresh oil, waste oil, or antifreeze of specific hardly inflammable classes.

Maintenance and Troubleshooting

Pre-use Inspection

Check all parts in contact with medium for leaks/damages before each use.

Maintenance Unit Refill

Always refill the compressed air maintenance unit with appropriate oil.

Waste Oil Spills

Pick up and properly dispose of spilled waste oil to prevent soil/sewerage pollution.

Disposal

Equipment Emptying

Completely empty all equipment parts (hoses, pumps, tanks) and blow out case with air.

Dangerous Parts Neutralization

Make dangerous parts unusable, e.g., perforate pressure vessels or deform hose reels.

Material Separation and Disposal

Separate materials like rubber, metals, glass and dispose according to local regulations.

Warranty

Warranty Void Conditions

Warranty void if maintenance is insufficient, operation faults occur, or non-adequate parts are used.

Manufacturer Liability

Manufacturer not liable for improper container use or ignoring safety instructions.

Technical Modifications

Technical modifications are subject to change without prior announcement.

Rapid OP 90 D 35/1 Specifications

General IconGeneral
BrandRapid
ModelOP 90 D 35/1
CategoryWater Pump
LanguageEnglish