User Manual
WARNING:
• Handle with care, the tip of the probe is sharp and can cause injury.
To measure temperature in °C / °F follow the simple instructions.
• Switch on the thermometer by clicking the ON/OFF button once. (See fig 1)
The LCD will display the temperature. The thermometer will automatically
power off, after 15mins if no activity.
• Select the function you wish to measure in. °C (Celsius) or °F (Fahrenheit) by
pressing the °C/°F button once. (see Fig 1) The LCD shows the selected icon
in the bottom right hand corner.
• Remove the protective sheath from the stem probe.
• Insert the tip of the probe into the area or object to be tested (Only the first
20mm from the tip of the thermometer probe will gain an accurate reading/
temperature measurement).
• The Raptor stem thermometer has a DATA HOLD function, that can also show
Max/Min measurement achieved.
• To use the HOLD function simply press the HOLD button once (see Fig1) This
will show the icon HOLD on the right of the temperature reading.
• To show the Maximum (MAX) temperature recorded simply press the HOLD
button once more and the MAX icon will show on the top right.
• To show the Minimum (MIN) temperature recorded simply press the HOLD
button once again and the MIN icon will show below.
• To switch off the thermometer, press the ON/OFF button once. (See fig 1) Or
the thermometer will automatically power off, after 15mins if no activity.
• Always re-cover the stem probe with protective sheath after use to prolong
the life of the instrument.
• The thermometer will display “ ” icon when battery is running low. Replace
battery with CR1220 3V button cell.
• To replace the battery turn the battery compartment anti-clockwise (OPEN),
this will release the battery cover, insert battery with (+) of battery facing
outwards, Push battery cover back in place and turn clock-wise to lock.
see Fig2:
Technical
Temperature Range:
-50°C ~ 330°C / -58°F ~ 626°F
Accuracy:
± 0.5% of reading ± 1.5°C (2.7°F)
Resolution:
0.1°C/°F
Out of Range Reset:
Should the thermometer go out of range:
Below -50°C the LCD panel will show “LO”
Above 330°C the LCD panel will show “HI”.
To reset the thermometer remove the battery completely, leave for
approximately 10 seconds, then replace battery.
IP Rating 54
Power:
1 x 3V “CR1220” Button Cell
Features
• 145mm x 4mm Stainless steel probe.
• 11mm LCD Display
• °C/°F Button.
• Max/Min/Hold Function.
• Low Battery Indicator.
• Auto Power off (after 15mins) if no activity.
• Over range indicator.
• Combined Pocket clip/wall hanger.
Fig.1
°C / °F Selection
Hold / Max /
Min Button
ON/OFF
Fig.2
Battery
Compartment
Pocket Clip /
Wall Hanger
180111800001
Question and Answer IconNeed help?

Do you have a question about the Raptor RAP130 and is the answer not in the manual?

Summary

User Manual

WARNING

Handle with care, the tip of the probe is sharp and can cause injury.

Operation Instructions

Step-by-step guide for switching on, selecting units, measuring, and using HOLD function.

Technical Specifications

Temperature Range

Specifies the operational temperature limits for the thermometer in Celsius and Fahrenheit.

Accuracy

Details the measurement precision of the thermometer, including percentage and offset values.

Resolution

Indicates the smallest temperature unit the thermometer can display.

Out of Range Reset

Instructions for resetting the thermometer when it displays 'LO' or 'HI' out-of-range indicators.

IP Rating

Specifies the degree of protection against dust and water ingress.

Power Source

Identifies the type of battery required for the thermometer's operation.

Product Features

Probe and Display

Details the stainless steel probe dimensions and the LCD display size.

Functional Capabilities

Lists key functions like °C/°F selection, Max/Min/Hold, low battery indicator, and auto power off.

Design and Portability

Highlights the combined pocket clip/wall hanger for convenient storage and use.

Limited Warranty Information

Raptor RAP130 Specifications

General IconGeneral
TypeInfrared Thermometer
Measurement Range-50°C to 1300°C (-58°F to 2372°F)
Optical Resolution50:1
DisplayLCD with backlight
Battery Type9V battery
EmissivityAdjustable from 0.10 to 1.00
Spectral Response8~14um
Battery Life12 hours (continuous use)
Accuracy±1.5% or ±1.5°C
Response Time500 ms