1
ICER-ETTE™
MODEL 84 and 85 AUTOMATIC ICE CUBE MAKER
INSTALLATION, OPERATION, MAINTENANCE AND TROUBLESHOOTING
WARNING: Raritan Engineering Company, Inc. recommends that a qualified technician install, troubleshoot
and repair this product. Equipment damage, injury to personnel or death could result from
improper installation. Raritan Engineering Company, Inc. accepts no responsibility or liability
from damage to equipment, or injury or death to personnel that may result from improper
installation of this product.
WARNING: Refrigeration Equipment contains refrigerant fluids under very HIGH PRESSURE. Danger of
sudden pressure release may cause injury, death or severe frostbite resulting from not following
instructions.
CAUTIONS:DO NOT plug a 120 volt unit into a 240 volt power source.
DO NOT plug a 240 volt unit into a 120 volt power source.
DO NOT use a transformer to step down 240 volt 50 HZ power supply to 120 volt.
Equipment designed for 60 HZ may run slow on 50 HZ, resulting in inferior operation and possible
overheating of the motor(s).
WARNING: This device is not ignition protected. DO NOT install in compartments containing gasoline tanks
or in areas in which
ignition protected equipment is required.
INTRODUCTION
Series 84 and 85 Icer-ettes are CFC-Free automatic
icemakers designed and manufactured especially for
the marine environment. They produce up to 22 lbs
(10kg) of crescent shaped ice per day and can store 11
lbs (5kg). Two cabinet configurations are offered,
allowing counter height installations and shorter
limited height installations. Installation and
maintenance are simple because no drain is required
and the thermostat is fixed; never needing adjustment.
OPERATION
The Icer-ette's on-off switch is just beneath the door.
A unit begins to produce ice within 60 minutes after
start-up. Ice production stops automatically when
the bucket is full enough to interfere with the wire
shut-off arm. The unit should not be turned "off" with
the door closed and ice or water inside.
NOTES:
1. Due to fast freezing, ice cubes may appear
"cloudy". This is trapped air in the water and
does not affect the taste or quality of the ice.
2. "Hollow" ice cubes may result from fast-
freezing under certain climatic conditions such
as high humidity, etc. and is not an indication
of a problem with the icemaker.
MAINTENANCE
Periodically vacuum dust and dirt from the condenser,
located behind louvered grill at the bottom front of
the unit; taking care not to damage aluminum fins in
the process. Regularly inspect plumbing connections
to insure that no leaks are present.
When necessary, defrost and thoroughly clean the
inside of the unit with mild soap and water. Do not
use electrical heating devices, sharp or pointed tools
when defrosting. When defrosting or leaving the unit
turned off, prop and leave the door open using door
lock link. This allows air to dry the inside of the
cabinet, reducing the chance for mildew and damage
to the mold mechanism's components.
WINTERIZING
WARNING: Disconnect power at source before
working on the unit. Do not winterize this unit
with ANY type of anti-freeze; damage to the mold
coating will occur, invalidating product's Limited
Warranty and creating potential health hazard.
1. Shut off the water supply to the unit.
2. Disconnect as follows:
Model 85: Disconnect water supply connector behind
front grille at solenoid valve (garden hose connector).
Remove white plastic tubing and nut from bottom of
solenoid valve.
Model 84: Disconnect the in-line water supply
connector behind the front grille.
3. Turn power on. Allow unit to run for an hour.
Remove any cubes that may have been ejected

Questions and Answers

  • K
    kimberlygarrettAug 13, 2025
    How to troubleshoot a Raritan ICER-ETTE 84 when the compressor and fan are not running?
    • S
      Samuel JonesAug 13, 2025
      If your Raritan Ice Maker's compressor and fan aren't running, here's what you can check: * First, ensure the breaker is on to restore AC power. * Next, inspect the AC power switch for loose connections; replace it if necessary. * If those aren't the issue, you might need to replace the compressor relay or the icemaker module. * Finally, consider replacing the cold control.
  • J
    Jay JonesAug 17, 2025
    Why is my Raritan Ice Maker making ice cubes at a very slow rate?
    • J
      Jamie DavisAug 17, 2025
      If your Raritan Icer-ette is making ice cubes too slowly, consider the following: 1. Replace the ice mold thermostat. 2. Replace the fan motor. 3. Check the installation section for ventilation issues. 4. Clean the condenser, referring to the maintenance section. 5. If there's too much water in the mold, contact Raritan Technical Support. 6. Replace the ejector relay.
  • K
    Kaitlyn HillAug 21, 2025
    Why is my Raritan ICER-ETTE 84 Ice Maker not cold enough to freeze ice cubes?
    • A
      Andres BarryAug 21, 2025
      If your Raritan Icer-ette will not get cold enough to freeze cubes, consider the following potential solutions: * Return to Raritan for compressor replacement. * Contact Raritan Technical Support regarding a refrigerant leak in the system. * Replace the fan motor. * Clean the condenser (see maintenance section). * Straighten the fan brackets if the fan is jammed. * Refer to solutions 1A, B, and C for additional troubleshooting steps. * Replace the icemaker module.
  • J
    jenniferburchAug 25, 2025
    What to do if my Raritan ICER-ETTE 84 Ice Maker freezes but doesn't produce ice?
    • Q
      qwilliamsAug 25, 2025
      If your Raritan Icer-ette freezes but water does not come into the mold, resulting in no ice production, consider the following: * Clean or replace the solenoid valve assembly. * Contact Raritan Technical Support regarding the mold heater assembly. * Ensure pressurized water is provided to the unit. * Replace the icemaker module. * Replace the cold control. * Contact Raritan Technical Support regarding bad wiring harness plug contacts.
  • R
    Rachel DelacruzAug 28, 2025
    Why won't my Raritan Ice Maker eject the ice cubes?
    • T
      Tammy MendezAug 28, 2025
      If your Raritan Icer-ette freezes cubes but will not eject them, try the following: * Replace the ice mold thermostat. * Replace the icemaker module. * Replace the ejector relay. * Replace the icemaker module (mold and heater assembly). * Contact Raritan Technical Support regarding bad wiring harness plug contacts.
  • C
    Colleen WatsonSep 1, 2025
    What to do if my Raritan Ice Maker has excessive ice accumulation and overflows?
    • B
      Bruce PorterSep 1, 2025
      If your Raritan Icer-ette is accumulating excessive ice, causing water to overflow, resulting in a solid block of ice, the following steps may help: * Try replacing the solenoid valve assembly. * Replacing the icemaker module may also resolve the issue. * Adjust the filler tube alignment to prevent splash over. * Consider replacing the icemold thermostat.
  • J
    Jonathan CarneySep 5, 2025
    How do I stop my Raritan Ice Maker from frosting up inside?
    • J
      Jasmine WadeSep 5, 2025
      If your Raritan Icer-ette frosts up inside and requires frequent defrosting, consider these solutions: * Replace the door gasket. * Ensure the door is not left open and defrost as needed.
  • K
    Kevin SpencerSep 9, 2025
    What to do if my Raritan ICER-ETTE 84 Ice Maker stops during the ejection cycle?
    • K
      Kayla GriffithSep 9, 2025
      If your Raritan Icer-ette stops in mid-ejection cycle and the compressor won't restart, here are a few things to check: * Contact Raritan Technical Support regarding the limit switch in the wire harness. * Replace the icemaker module. * Check the power supply connections. * Replace the icemaker module (mold and heater assembly). * Contact Raritan Technical Support regarding bad wiring harness plug contacts.

Summary

Model 84 and 85 Automatic Ice Cube Maker Installation, Operation, Maintenance and Troubleshooting

Introduction

Provides an overview of the CFC-Free automatic icemakers for marine environments.

Operation

Details how to start, operate, and the automatic shut-off mechanism of the icemaker.

Maintenance

Outlines periodic cleaning of the condenser and defrosting procedures for the unit.

Winterizing

Instructions for preparing the unit for winter, including water disconnection and defrosting.

Recommissioning

Mounting

Plumbing

Wiring

Start-Up

Troubleshooting Section

Dimensions

Specifications

Limited Warranty

Save These Instructions

Overview

The Raritan Icer-ette Model 84 and 85 are automatic ice cube makers specifically designed and manufactured for the marine environment. These units are engineered to produce crescent-shaped ice and offer two cabinet configurations to accommodate various installation needs, including counter height and limited height spaces. A key design feature is that no drain is required, simplifying installation. The thermostat is fixed, eliminating the need for manual adjustments.

Function Description

The Icer-ette's primary function is to automatically produce and store ice cubes. Once the unit is turned on via the switch located just beneath the door, it typically begins ice production within 60 minutes. The ice production process is automated: it stops when the ice bucket is full enough to interfere with a wire shut-off arm, indicating that the storage capacity has been reached. The unit should not be turned off while the door is closed and ice or water are inside, as this can lead to issues.

The ice-making process involves a fan and compressor that activate upon start-up, circulating air through the grille and producing a faint hum. If the machine was previously shut off during an ice harvesting cycle, it will first complete that cycle (approximately 5 minutes) before the compressor and fan fully engage. The internal temperature will drop below freezing, and the first batch of ice is usually harvested within 60 minutes. After the water lines are purged of air, normal harvesting and refilling cycles occur every 40 minutes or less under typical operating conditions.

Usage Features

The Icer-ette is designed for straightforward use. The on-off switch is easily accessible beneath the door. For built-in installations, a minimum of 3/4" (2cm) clearance is required behind the unit for the water line and plug. The units are designed for zero clearance at the top and sides, utilizing fan-forced condenser cooling, which necessitates proper air circulation through the lower section of the unit. Recirculation between the fresh air intake and exhaust air must be prevented to ensure optimal performance.

The unit must be placed on a secure, level surface, and the mounting flange should not be used to support its weight. When installing within cabinetry, it's important to ensure that the unit can be easily removed for servicing and that the door has its full range of motion. While doors are hinged on the right, they can be reversed in the field if needed.

For plumbing, a minimum water pressure of 22 P.S.I. (152kPa) is required for the water valve to operate correctly. Model 85 units require removing the front grille to run a 1/4" O.D. water line through a provided hole at the rear of the cabinet and attach it to the garden hose adapter on the solenoid water valve. Model 84 units come with an 18" (45cm) water line extending from the back with a 1/4" plastic female compression fitting. No drains are required, only a water supply.

The Icer-ette operates on 120 volts 60 HZ AC (alternating current) with a three-wire grounded plug, or 240 volts 50HZ AC (alternating current) with a Euro-plug. Extension cords or plug adapters should not be used, and the ground prong should never be removed from the plug to prevent electric shock hazards.

A few notes on ice quality: due to fast freezing, ice cubes may appear "cloudy" due to trapped air, which does not affect taste or quality. "Hollow" ice cubes can also occur under certain climatic conditions like high humidity and are not an indication of a problem with the icemaker.

Maintenance Features

Regular maintenance is crucial for the longevity and optimal performance of the Icer-ette. Periodically, dust and dirt should be vacuumed from the condenser, which is located behind the louvered grill at the bottom front of the unit. Care must be taken not to damage the aluminum fins during this process. Plumbing connections should be regularly inspected to ensure there are no leaks.

When necessary, the inside of the unit should be defrosted and thoroughly cleaned with mild soap and water. It is important not to use electrical heating devices or sharp/pointed tools for defrosting. When defrosting or leaving the unit turned off, the door should be propped open using the door lock link. This allows air to circulate and dry the inside of the cabinet, reducing the chance of mildew and preventing damage to the mold mechanism's components.

For winterizing, it is critical to disconnect power at the source before working on the unit. Anti-freeze of any type should NOT be used to winterize this unit, as it will damage the mold coating, invalidate the product's Limited Warranty, and create a potential health hazard. The winterizing process involves shutting off the water supply, disconnecting the water supply connector (at the solenoid valve for Model 85, or the in-line connector for Model 84), and then turning on power to allow the unit to run for an hour. Any ejected cubes should be removed. After this, turn off power, prop the door open to defrost, wipe dry, and leave the door open.

For recommissioning, simply connect the water supply lines, turn on the water, check for leaks, and then restore power to the unit. After an initial cool-down period of 45-60 minutes, the unit will resume its normal cycle of approximately every 40 minutes.

Raritan ICER-ETTE 84 Specifications

Model 84

Weight and Dimensions IconWeight and Dimensions
recess height18 1/2" (47cm)
recess width14 1/2" (36.9cm)
recess depth23" (58.4)

Model 85

Ice Production IconIce Production
ice production per day22 lbs. (10kg)
ice storage capacity11 lbs. (5kg)
refrigerant charge2.4 oz. (68 grams) R-134A
Water Supply IconWater Supply
minimum water supply pressure22 psi (152kPa)
maximum water supply pressure125 psi (863kPa)
max. amp draw120 Volt - 2.5; 240 Volt - 1.3