Required calibration cards: 1 x pink calibration card, 10 x grey calibration cards,
10 x white calibration cards
CALIBRATION INSTRUCTIONS rapidcount T 575
EN
ratiotec GmbH & Co. KG | Tel.: +49 201 361 490 | Fax: +49 201 361 49 26 | Email: info@ratio-tec.de
Connect the power adapter with the device.
Turn on the device. Then press the “CLEAR“
button times. A window with „Input Pass-
word“ opens on the display . Please enter a 0
and conrm it with the “START button.
Now the “Maintenance Menu“ opens. Select
“Sensor Adjust“ and conrm it with the
“START button. Afterwards please press the
“REPORT button to get to “Static Adjust“.
Conrm it again with the START button.
Open the cover of the device so that the feed
rollers are visible. Place the pink calibration
card centrally under the feed roller. Then close
the cover and press the START button. The
calibration card is automatically ejected after
the calibration.
Press the “REPORT button to get to “Image
Dynamic Adjust. Conrm it with the START
button. Place all gray calibration cards on the
upper feed. Repeat this process until “Press
START key“ is shown.
pink
calibration card!
grey
calibration cards!

Other manuals for ratiotec rapidcount T 575

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ratiotec rapidcount T 575 and is the answer not in the manual?

ratiotec rapidcount T 575 Specifications

General IconGeneral
Brandratiotec
Modelrapidcount T 575
CategoryBanknote Counter
LanguageEnglish

Related product manuals