30
·
ELECTRIC STARTING
• The battery will release the explosive gas, please keep the re far
away from it. Keep a good air ventilation condition when battery
is being charged or used.
.
• Be careful not to spill or overow when relling electrolyte.
3. Electric Starting
(1) Remove all the loads form the output side.
(2) Turn the fuel valve to the “ON” position.
(3) Turn the AC circuit breaker to the “OFF” position.
(4) Turn the choke lever to the “CLOSE” position.
Don’t close the choke when starting the engine in warm state.
(5) Turn the GENERATOR switch to electric starting position.
(6) After starting engine, immediatelly release generator switch and
generator switch can automatically return to open position.
(7) Turn the choke lever to the “OPEN” position after the engine is
warm.
Turn the GENERATOR switch to electric position and hold for
more than 5 seconds or damage may be caused to the starting motor.
If starting fails,, release the switch and wait for 10 seconds before
starting it again.
If the speed of the starting motor drops fast after a period of time, it
suggests the battery should be recharged.