Hydraulic system
Topic: Hydraulic block layout
RAUCH Landmaschinenfabrik GmbH D-76547 Sinzheim
Customer service hotline: +49 (0)7221 985 250
E-mail: service@rauch.de
Page
3
of
3
04.11.2014
Chapter 510
6. Arrangement of the components in the circuit diagram
2
10 17 18
8 7
14
1
19 3
6
13
11/12
15
4
4
5
9
(1) Proportional valve, oil motor, right-hand side
(2) Proportional valve, oil motor, left-hand side
(3) Input pressure scales, complete with adjustment screw for load sensing/constant
current conversion
(4) Sealing plugs for measurement connection ¼
(6) Pressure sensor 40bar
(7) Pressure scales, oil motor, right-hand side
(8) Pressure scales, oil motor, left hand side
(9) Connection, free return flow T
(10) Connection, pressure P
(11) Return flow from the oil motor, right-hand side
(12) Return flow from the oil motor, left-hand side
(13) LS signal connection
(14) Non-return valve for LS signal, oil motor, right-hand side
(15) Non-return valve for LS signal, oil motor, left-hand side
(17) Connection P, oil motor, right-hand side
(18) Connection P, oil motor, left-hand side
(19) Non-return valve to oil motors