TECHNICAL INFORMATION - SERVICE
Page 3 of 4 2014-09-03_TI_AXIS-HEMC_Freigabe-Software-V3-01-00-EN(UK)
Automatic calculation of the VariSpread
section table
The VariSpread table is automatically calculated
after entering the data on page 1-4.
If the table is changed directly (working width, DP,
RPM), -0% instead of AUTO is displayed in the last
column. With the “Calculate VariSpread” function,
the required new calculation has to be carried out
manually.
Figure 7
If all sections of one side are deactivated, the larger
DP is now automatically set to reduce the reaction
time at reactivation.
Figure 8
The electrical hopper cover is controlled via LIN Bus.
It is activated in the machine options.
In the main menu, the operating side (figure 9) is
selected with the “Hopper cover” soft key.
Figure 9
The “Hopper empty!” alarm is displayed if a
predefined minimum weight is reached.
The weigh cell-based level sensor is activated in the
machine options and the minimum weight is entered
in the machine settings.
Figure 10