Ravelli Camino - User Manual

Ravelli Camino
39 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
economicaluser
friendly
leading
design
healthy
home
visible clean air
approved
Camino Wood Pellet
& Installation Manual
Fire Owners
PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS WOOD PELLET FIRE.
FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR
EVEN DEATH.
Contact your local building or about restrictions and installation inspection requirements in your area.

Table of Contents

Questions and Answers

  • D
    Douglas DickersonJul 31, 2025
    What to do if my Ravelli Camino Pellet stove shows a 'Pellets Finished Alarm'?
    • A
      Anita MartinezJul 31, 2025
      If your Ravelli Pellet stove displays a 'Pellets Finished Alarm', it could be due to a couple of reasons. First, check the pellet hopper to ensure it's not empty and refill if needed. Alternatively, the issue might be that the auger is blocked, preventing pellets from loading. In this case, empty the hopper and check for any foreign objects that may be obstructing the auger's function.
  • R
    rebecca35Aug 4, 2025
    Why does my Ravelli Camino Pellet stove show a 'No Ignition Alarm'?
    • Y
      yjacksonAug 5, 2025
      If your Ravelli Pellet stove is showing a 'No Ignition Alarm', it could be due to a few reasons. The pellet hopper might be empty, so check and refill if necessary. Also, the settings of pellets and of intake during the ignition phase might be insufficient.
  • L
    Lacey BurtonAug 9, 2025
    What causes a 'Depression Alarm' on a Ravelli Camino and how to fix it?
    • C
      Curtis LoveAug 9, 2025
      If your Ravelli Pellet stove displays a 'Depression Alarm', there are a few things you can check. First, the combustion chamber may be dirty, so follow the cleaning operations of the stove as per the instructions manual. Second, the flue might be blocked, so check that it is clear and clean.
  • M
    Matthew JonesAug 13, 2025
    What should I do if my Ravelli Camino Pellet stove displays a 'Low Flame Alarm'?
    • G
      Greg SanchezAug 13, 2025
      If your Ravelli Pellet stove is showing a 'Low Flame Alarm', it may be because the pellet hopper is empty; check and refill it if necessary. Another possible cause is a bad setting of pellet and air during ignition.
  • P
    Peter SimmonsAug 17, 2025
    How to fix a 'Thermal Alarm With Reset' on my Ravelli Camino Pellet stove?
    • J
      Jeremy BassAug 17, 2025
      If you are getting a 'Thermal Alarm With Reset' on your Ravelli Pellet stove, it could be because the thermostat with manual reset has intervened. To solve this, reset the thermostat by pressing the button on the back of the stove. Another possible cause is non optimal combustion in the fire pot. To solve this, switch off the stove, clean the fire pot and regulate combustion with the setting of the pellets.
  • A
    Angela RamirezAug 21, 2025
    What to do if my Ravelli Camino Pellet stove shows 'Black-Out'?
    • C
      christinesmithAug 21, 2025
      If your Ravelli Pellet stove experiences a 'Black-Out' during operation due to no electricity supply, press the off button and repeat switching on the stove.
  • A
    Adam CarlsonAug 26, 2025
    What does a 'Hot Smoke Alarm' on my Ravelli Pellet stove mean, and how can I resolve it?
    • M
      Michael TrevinoAug 26, 2025
      If your Ravelli Pellet stove is showing a 'Hot Smoke Alarm', it may be caused by non optimal combustion in the fire pot. To address this, switch off the stove, clean the fire pot, and regulate combustion with the setting of the pellets.

Summary

ATTENTION

Introduction

Specifications

Technical details and rating label location for the wood pellet fire.

Safety Warnings & Maintenance Recommendations

Pellet Quality

Importance of using correct wood pellets for performance and warranty.

Flammable Liquids

Warnings against using flammable liquids for starting or operating the fire.

Fire Pot Cleaning Procedure

Steps for cleaning the burn pot liner to ensure proper combustion.

What are Wood Pellets?

Maintenance and Cleaning Guide

Pre-Maintenance Precautions

Safety checks and precautions to take before performing maintenance.

Manufacturer Responsibility and Limitations

Outlines responsibilities of Pellet Fire Solutions and user obligations.

Operating Your Pellet Fire

First Time Fire Start-up

Step-by-step guide for the initial ignition and commissioning of the fire.

Pellet Hopper Filling Guide

Instructions on how to safely load pellets into the hopper.

Troubleshooting Guide

Explanation of Alarms and Faults

Lists display codes, reasons, and solutions for common alarms.

Routine Maintenance and Cleaning

Daily Burn Pot Liner Cleaning

Procedure for daily inspection and cleaning of the burn pot.

Flue System Inspection (Yearly)

Yearly inspection and cleaning of the flue system.

Warranty Information

Warranty Coverage Details

Outlines what the warranty covers for the pellet fire.

Warranty Exclusions

Lists conditions and events not covered by the warranty.

Positioning and Installation Guide

Installation Procedures

Steps and requirements for installing the Ravelli Camino Wood Pellet Fire.

Installation Safety Warnings

Installer Responsibility

Declines responsibility for accidents due to improper installation.

Creating the Installation Cavity

Cavity Clearances to Combustibles

Minimum safe clearances from the cavity to combustible materials.

Ventilation Requirements

Importance of proper ventilation for combustion and performance.

Architectural Drawings

Cavity Design Section View

Illustrates a cross-section of a compliant cavity design.

Controls and Menus

Description of Controls

Explains the function of each button on the remote control.

Setting the Clock

Instructions to set the appliance's internal clock.

Language Selection

Steps to change the display language to user preference.

Stove State Monitoring

Checking the operational status of key components.

Programming & Commissioning

Camino Parameters (BOX 03)

Table of configurable parameters for the BOX 03 version.

Technical Drawings

Producer Registration Form

Ravelli Camino Specifications

General IconGeneral
Fuel TypePellets
Pellet Consumption0.5 - 1.8 kg/h
Width480 mm
Depth370 mm
Height850 mm
Flue Diameter80 mm