DISTRIBUTION UNIT
Type 138--118
1 Description
2 Installation
Question and Answer IconNeed help?

Do you have a question about the Raytheon 138-118 and is the answer not in the manual?

Raytheon 138-118 Specifications

General IconGeneral
BrandRaytheon
Model138-118
CategoryPower distribution unit
LanguageEnglish

Summary

General Unit Information

CAN Bus System Overview

Explains the CAN bus network architecture, addressing, and termination requirements for device communication.

Technical Specifications

Details electrical supply, current, input, and output interfaces of the distribution unit.

Interface PCB Component Details

Identifies LEDs, push buttons, jumpers, and connectors on the distribution unit's interface PCB.

Installation Procedures

Cable Connection and Preparation

Provides instructions on stripping cables, preparing shielding, and making general connections for system installation.

Establishing Proper Earth Connections

Details the process for creating common earth references for EMC compliance and system integrity.

Distribution Unit and Option Mounting

Covers physical mounting of the unit and installation of optional accessories like the AC/DC-Converter.

Terminal Board and Plug Connections

General notes on making connections according to drawings and considering cable diameters.

Powering On the Distribution Unit

Setting of Jumpers and DIP-Switches

CAN Bus Terminator Jumper Settings

Describes the function of jumpers B31 and B32 in activating CAN bus terminators for network integrity.

DIP-Switch and Push Button Usage

Guides on using DIP-Switch B20 and push buttons B22/B23 for mode selection and setting.

Setting the CAN Bus Address

Procedure for assigning unique CAN bus addresses to devices to avoid conflicts.

Configuring Output Channel Interfaces

Explains how to set output channels to Course bus, NMEA1, or NMEA2 interfaces.

Switching OFF the Distribution Unit

Adjustments

Adjusting the Magnetic Sonde

Detailed steps for calibrating the magnetic sonde using test points and potentiometers.

Maintenance and Repair Procedures

Service Mode DIP Switch Functions

Gyro Compass Data Display

Displays uncorrected heading data for Gyro compasses 1, 2, and 3 via DIP switch settings.

Magnetic Compass Data Display

Shows magnetic compass heading, variation, and deviation values as adjusted by DIP switches.

NMEA Telegram Configuration

Guides on setting NMEA telegram requests and interpreting received NMEA data strings.

Software Version Display

Displays software versions for the CAN-bus processor and the I/O-PCB of the distribution unit.