EasyManuals Logo

RBH Access Technologies UNC100 User Manual

RBH Access Technologies UNC100
3 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
1 2 3 4 5 6 7 8
TX RX
A+
FG
B-
Input 1(RTE)
C
Input 2 (DC)
RTE “A”- Request to Exit
DC “A” - Door contact
RTE “B”- Request to Exit
DC “B” - Door contact
Input 3
C
Input 4
Reader B
GRN
BUZ
D0
D1
S
0V
12V
LED (For single LED readers)
Buzzer
Data 0
Data 1
0V, Power, Data Ground
+12VDC
Reader A
LED (For single LED readers)
Buzzer
Data 0
Data 1
0V, Power, Data Ground
+12VDC
GRN
BUZ
D0
D1
S
0V
+12V
1NO 1NC 1C 2OC
Output 1 Lock “A”
Output 2
Output 3 Lock “B”
Output 4
Lock
Lock Power Supply
12-24 VDC
- +
0V
IN 13.5V@1.5 A
+V
OUT 12V@500 mA
THIS DOCUMENT IS FOR QUICK REFERENCE ONLY, REFER TO HARDWARE & SOFTWARE MANUALS FOR FULL DETAILS
Panel LEDs Run Trouble Host Comm TX RX
Function Heartbeat Trouble Com to
software
RS-485
transmitting
RS-485
receiving
Off Malfunction Normal No com No com No com
Solid Malfunction Trouble No Com Malfunction Malfunction
Blinking Normal Trouble Red/Green =
Normal
Normal Normal
Panel LEDs
Cycle power for DIP-switch changes to take effect!
Switch 1 2 3 4 5
Panel 1 On
Panel 2 On
Panel 3 On On
Panel 4 On
Switch 1 2 3 4 5
Panel 9 On On
Panel 10 On On
Panel 11 On On On
Panel 12 On On
Switch 1 2 3 4 5
Panel 13 On On On
Panel 14 On On On
Panel 15 On On On On
Panel 16 On
Switch 1 2 3 4 5
Panel 5 On On
Panel 6 On On
Panel 7 On On On
Panel 8 On
Switch 6 7
9.6 K
38.4 K On
57.6K On
115.2 K On On
Switch 8: Always OFF!
DIP SWITCH SETTINGS : DIP-Switch: UP = ON / DOWN = OFF
Lock
Lock Power Supply
12-24 VDC
+ -
Link up to 15 additional
panels via RS-485
Belden 8723 20-22 AWG Twisted,
Shielded Pair. 4,000’ Max
To 12 VDC 7 Ah UL Listed
Rechargeable Battery (REQUIRED)
0VDC @ 2A
+12VDC @ 2A
PS-1224 Power Supply
BAT. TEST
16.5VAC 40Va
16.5VAC 40Va
Press “BAT. TEST” button on
PS-1224 for battery test, Yellow
LED will go ON if test failed
Power Supply (PS-1224) LEDs
LED On Off
Green LED Power On Power Off
Red LED Shorted OK
Yellow LED Battery Fail Battery OK
For Support Call : 01386 425810
All software and hardware manuals are included
on software DVD in “Documents” folder
!
Web site : www.rbhsecuritygroup.com E-mail : support.uk@rbh-access.com
UNC100
Universal Network Controller
with ENCL1 enclosure
and PS-1224 power supply
RUN
TROUBLE
HOST COM
CANADA
ETHERNET
PoE
RS-485
(max 100ma)
LOCK 1
3NO 3NC 3C 4OC
(max 100ma)
LOCK 2
Firmware, use Axiom Lite
software to check
firmware version.
Verify it matches your
software, up/downgrade
as needed via firmware
upgrade utility.
REMEMBER TO REMOVE THE PAPER FROM THE BATTERY CONTACT PRIOR TO INSTALLATION
Belden 9538 20-22 AWG
8 core screened for
readers.
Belden 9538 20-22 AWG
8 core screened for
readers.

Other manuals for RBH Access Technologies UNC100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the RBH Access Technologies UNC100 and is the answer not in the manual?

RBH Access Technologies UNC100 Specifications

General IconGeneral
BrandRBH Access Technologies
ModelUNC100
CategoryIP Access Controllers
LanguageEnglish