Integrated Access Control and
Security Management System
HARDWARE MANUAL
new generation
building security

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the RBH Sound Axiom V and is the answer not in the manual?

Summary

Network Controller NC-100

NC-100 Connection Details

Details power supply requirements and host interface options for connecting the NC-100.

NC-100 DIP Switch Configuration

Configuration settings via DIP switches for addressing, baud rate, direct connect, and RS485 interface.

NC-100 Network Interfaces and Diagrams

Explains C-NET and D-NET interfaces, connection diagrams, and network topology.

NC-100 Cable Specifications

C-NET cable types, lengths, and related specifications.

NC-100 Status LEDs

Interpretation of status LEDs for computer port, network communication, and system run status.

NC-100 D-NET Cable and Termination

D-NET cable types, lengths, shielding, and termination requirements.

Clearing NC-100 Memory

Procedure for performing a complete memory reset on the NC-100 controller.

Reader Controller RC-2

RC-2 Connection Details

Terminal connections for all RC-2 outputs, inputs, power supplies, and battery backup.

RC-2 DIP Switch Settings & Status LEDs

Configuration of RC-2 address using DIP switches and understanding operational status LEDs.

RC-2 Inputs & Circuit Types

Description of RC-2 inputs, including RTE, door contact, and various supervised input circuit types.

RC-2 Outputs & Operating Modes

Explanation of RC-2 output functions, default operations, and access point operating modes.

RC-2 Reader Connection Diagrams

Wiring diagrams for connecting various readers and keypads to the RC-2 controller.

Input;Output Controller IOC-16

IOC-16 Connection Details

Covers power, battery backup, fire release input, and tamper switch connections for the IOC-16.

IOC-16 DIP Switch Settings & Addressing

Configuration of IOC-16 address and DIP switches for input/output selection and fail-safe operation.

IOC-16 Status LEDs & Diagnostics

Understanding IOC-16 status indicators, battery tests, and protection mechanisms.

IOC-16 Input;Output Configuration

Methods for programming IOC-16 ports as inputs or outputs via hardware and software.

IOC-16 Elevator Control

Implementing elevator access control using IOC-16, including wiring and fail-safe logic.

NRC2000 & NURC2000 Controllers

IRC2000 Wiring Diagram

Visual guide for wiring the IRC2000 board used in NRC2000/NURC2000 systems.

NRC2000;NURC2000 System Wiring

Instructions for connecting NRC2000 and NURC2000 units to the NC-100 controller.

NRC2000 Modifications

Details on necessary modifications for NRC2000 units due to hardware limitations.

PC-100 Interface Module

PC-100 Power and LEDs

Details on the PC-100's power requirements and the function of its status LEDs.

RBH Sound Axiom V Specifications

General IconGeneral
BrandRBH Sound
ModelAxiom V
CategorySecurity System