IS9212iLW
Features:
• FlushMount,SingleGang
•IlluminatedBacklitKeys
•KeypadProgrammable
• KeypressFeedbackviaBuilt-InSounder
•Bi-ColorRed/GreenLEDIndicatesRelayStatus
•YellowLEDIndicatesProgramMode
•120Users
•SingleUseCodes
•LockoutUsers
•Passage/ToggleCodes
•10to30VoltDCOperation
•12to24VoltACOperation
•2AmpMainRelay
•RemoteTriggerInput(REX)
• 2YearWarranty
Product Description:
The212iLWkeypadfeaturesasingle-relayoutputtocontrolany
devicerequiringanon/offswitch.Theoutputistimedorlatchedand
operatedbyauser’sPINcode.Additionally,the212iLWkeypad
providesbasickeylessentrybycontrollingadoorlockingdevice
wheresecurityisnotanissue.
The212iLWstylekeypadsaredesignedforbothindoorandoutdoorush
mountapplications.Theelectronicsareconformalcoatedinthe
manufacturingprocessinordertoprovidethislevelofapplication
exibility.Inaddition,eachkeypaduseshardenedkeystoassurelong-term,
high-qualityperformance.
Eachkeypadcontainsilluminatedclearkeysthatmakeoperationinlow
lightsituationseasyandaccurate.iLWstylekeypadsmounttoanystandard
single-gangelectricalboxordirectlytoanywall.
Specifications:
Parameter Range/Description
Voltage 10–30VDC,12-24VAC(Auto-Adjusting)
Current 93mA@10VDC;158mA@30VDC,148mA@12VAC;198mA@24VAC
Environment ForIndoorandOutdoorUse
TemperatureTolerance -20°Fto130°F(-28°Cto54°C)
Dimensions 51/8”Hx33/8”Wx5/8”D
MainRelay(FormC) ContactRating:2A@30VAC/DC
REXInput NormallyOpenDryContact
DoorPositionInput NormallyClosedDryContact
LEDs Bi-ColorRed/Green;Yellow
Default Keypad Settings
Parameter Default Setting
MasterCode 1234
LockOutput Relay1(Mainrelay)
AudioAlerts Notassigned
REX TriggersLockOutput
REXOperation AlwaysTriggers(regardlessofDoorLoop)
ErrorLockout/Threshold Enabled/3Attempts
ErrorLockoutDuration 10seconds
LockOutputTime 5seconds
Visual/AudioKeypressFeedback Enabled
Auto-Entry Disabled
UserLockout
Enabled
PCN13023
R11/13CA
INSTALLATION
9212iLW
Interior/Exterior Use Stand-Alone Keypad
©2013 RutheRfoRd contRols • www.RutheRfoRdcontRols.com
usA: 2517 sQuAdRon couRt, suIte 104, VIRGInIA BeAch, VA 23453 • cAnAdA: 210 sheARson cRescent, cAmBRIdGe, on n1t 1j6
Phone • 1.800.265.6630 • 519.621.7651 • fAX: 1.800.482.9795 • 519.621.7939 • e-mAIl: sAles@RutheRfoRdcontRols.com

Questions and Answers

  • B
    Barry BerryAug 2, 2025
    What to do if no LEDs are lit on my RCI Keypad?
    • L
      lisabushAug 2, 2025
      If no LEDs are lit on your RCI Keypad, it likely means power isn't reaching the device. First, use a voltmeter to check for voltage on the red and black wires at the keypad. If there's no voltage there, check the power supply. If the power supply lacks voltage, contact its manufacturer. If the power supply has voltage but the keypad doesn't, inspect the wires for breaks and test the wire run for continuity. You can also test the keypad by powering it with a 12-Volt Battery.
  • B
    Benjamin EllisAug 9, 2025
    What to do if the master code does not work on RCI Keypad?
    • P
      Patrick MeyersAug 9, 2025
      If the master code on your RCI Keypad isn't working, perform the programming mode loopback and reset the master code using the programming command.
  • Z
    Zoe YoungAug 17, 2025
    Why are the LEDs rapidly cycling on my RCI Keypad?
    • J
      Jason DavisAug 17, 2025
      If the LEDs on your RCI Keypad are rapidly cycling from left to right and the keypad isn't working, it indicates an over-voltage issue. Verify the voltage is correct at the power supply.
  • M
    Michael BradleyAug 25, 2025
    How to fix LEDs slowly cycling on RCI 9212ilw Keypad?
    • E
      erin20Aug 26, 2025
      If the LEDs on your RCI Keypad are slowly cycling from right to left and the backlighting is off, it suggests an under-voltage situation. To fix this, increase the voltage to between 12-24V.

Summary

Product Overview

Features

Lists key attributes like flush mount, backlit keys, user capacity, and warranty.

Specifications

Details technical parameters like voltage, current, temperature, and dimensions.

Product Description

Explains the keypad's function as a single-relay output device for door control.

Installation Guide

Mounting

Instructions for flush mounting the keypad to a single gang box or wall surface.

Wiring Configuration

Details the wire harness pinout and signal names for keypad connections.

Wiring to Maglock (Fail-Safe)

Step-by-step guide to connect the keypad to a fail-safe maglock.

Wiring to Electric Strike (Fail-Secure)

Step-by-step guide to connect the keypad to a fail-secure electric strike.

Advanced Configuration

Shunting Normally Closed Zone

Instructions for connecting the keypad to shunt a normally closed zone.

REX and Door Contacts Wiring

How to wire Request to Exit (REX) devices and door contacts.

Keypad Testing

Procedure for performing a self-test to verify keypad functionality.

Programming and Operation

Entering Program Mode

Method to access programming using master code and sequence.

Programming Users

Details for adding, modifying, and managing user codes and types.

Programming Keypad Options

Configuration of keypad features like feedback, auto-entry, and illumination.

Programming Options Chart

Quick reference for programming commands and options.

Troubleshooting and Support

Troubleshooting Common Issues

Solutions for problems like LED cycling, non-working master code, and no LEDs.

Wire Harness Loopback

Procedure to enter program mode if the master code is lost or not working.

RCI 9212ilw Specifications

General IconGeneral
TypeKeypad
ModelRCI 9212ilw
Number of Keys12
BacklitYes
ConnectivityWired
IP RatingIP65
DisplayNo