MIGHTY PUMP™
2. push-out a condensate drain line
Connect the pressure end of the Mighty Pump™, using the enclosed coupling, to the upstream end of the condensate
line or item to be blown out. Note the direction of the FLOW arrow on the bottom of the pump body. Secure over ¾”
pipe with supplied clamp.
Figure 3: Pump arrangement using the discharge side.
3. Maintenance:
1. Clean unit after use by pumping clean water through unit until clean water is seen on the discharge side. A thorough, periodic
cleaning and inspection is recommended after several uses.
2. The check valves can be disassembled for inspection and cleaning if necessary.
3. Hoses can be removed for cleaning if necessary.
4. Remove pump body cap for thorough cleaning.
5. Lubricate O-rings with silicone grease every 6 months or as needed.
a. Remove the threaded cap and washer from the pump body.
b. Clean the washer, O-rings, rubber washer, and pump interior.
c. Lubricate with silicone grease
d. Check the condition of the O-rings. If they are visually worn or leaking, replace them with the supplied spares
or standard (AS568A 334 black Buna-N) O-rings.
6. Trouble Shooting
a. The pump is not pulling a vacuum
i. Check hose connection
ii. Check the connections on the suction side of the pump. If the connections are leaking,
use RectorSeal thread sealant or PTFE tape in the connections.
iii. Check for blockage of the hose or check valves
iv. Check the O-rings, if worn or in need of lubrication follow procedures described in item 4.
v. Check rubber washers on piston. Tighten plastic lock nut (14) or use silicone grease to seal.
b. The pump will not pressurize
i. Follow procedures described in section 6a.
For additional technical information, call Toll Free 1-800-231-3345
PRECAUTIONS
The device creates a minimum of 5-psi. Do not use on systems that are loose or not solvent cement welded
Do not vacuum or pressurize toxic, carcinogenic, combustible or other hazardous materials
Do not place vacuum hose end on any part of the body
Do not place any loose object(s) in the pressure side nozzle
Dispose of pumped liquids in an approved manner
LIMITED WARRANTY
RectorSeal, LLC makes the Limited Express Warranty that when the instructions for storage and handling of our products are followed we warrant our products to be free from defects.
THIS LIMITED EXPRESS WARRANTY IS EXPRESSLY IN LIEU OF ANY OTHER EXPRESS OR IMPLIED WARRANTIES, INCLUDING ANY IMPLIED
WARRANTY OF MERCHANT ABILITY OR FITNESS FOR A PARTICULAR PURPOSE, AND OF ANY OTHER OBLIGATION ON THE PART OF
RECTORSEAL, LLC. The sole remedy for breach of the Limited Express Warranty shall be the refund of the purchase price. All other liability is negated and disclaimed, and
RectorSeal, LLC shall not be liable for incidental or consequential damages.
MANUFACTURED BY
RectorSeal, LLC 2601 Spenwick Drive Houston, Texas 77055-1035, USA
Telephone: 713-263-8001 or 1-800-231-3345 Fax: 713-263-7577 or 1-800-441-0051
www.rectorseal.com
C-17