VENT-FREE GAS WALL
HEATER
OWNER’S OPERATION AND
INSTALLATION MANUAL
BLUE FLAME MODELS
BWH10NLMB
BWH20NLTD
BWH30NLTD
PFS
®
US
WARNING: If the information in this manual is not
followed exactly, a re or explosion may result causing
property damage, personal injury or loss of life.
Do not store or use gasoline or other ammable va-
pors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbors
phone. Follow the gas suppliers instructions.
If you cannot reach your gas supplier, call the re
department.
Installation and service must be performed by a quali-
ed installer, service agency or the gas supplier.
WARNING: This appliance is equipped for Natural and
Propane gas. Field conversion is not permitted other than
between natural or propane gases.
Questions, problems, missing parts?
Before returning to your retailer, call our customer service department at
1-800-229-5647, 8:00 am - 4:30 pm EST, Monday through Friday

Questions and Answers

  • I
    Ian NelsonAug 19, 2025
    Why is there no spark at the pilot light when I press the ignitor button on my ReddyHeater BWH10NLMB?
    • S
      Steven MooneySep 12, 2025
      If the ignitor button is pressed but there's no spark at the ODS/pilot of your ReddyHeater Gas Heater, several issues could be at fault. It might be due to incorrect positioning or breakage of the ignitor electrode, in which case you should replace the pilot assembly. Another cause could be that the ignitor electrode isn't connected to the ignitor cable, suggesting a need to replace the ignitor cable. The ignitor cable could also be pinched or wet, so free it from any obstructions and keep it dry. A broken ignitor cable would also need replacement. Lastly, a faulty piezo ignitor would also require replacement.
  • D
    deanjamesAug 21, 2025
    What to do if the pilot light goes out when I release the control knob on my ReddyHeater Gas Heater?
    • A
      Amy LewisAug 21, 2025
      If your ReddyHeater Gas Heater's ODS/pilot lights but the flame goes out when you release the control knob, ensure the control knob is fully pressed in and held for 30 seconds after the pilot lights. Check that the equipment shutoff valve is fully open. A loose thermocouple connection at the control valve can cause this issue; hand tighten it until snug, then give it an extra 1/4 turn. Low gas pressure or a dirty ODS/pilot can also be the reason. Contact your local gas company to check the gas pressure. Clean the ODS/pilot or consider replacing the ODS/pilot assembly. If the thermocouple is damaged, replace it. If the control valve is damaged, replace the control valve.
  • J
    jeffreyhansonAug 23, 2025
    What to do if there's a spark but no ignition on my ReddyHeater Gas Heater?
    • A
      Ashley BurnsAug 23, 2025
      If the ignitor button is pressed and there is a spark at the ODS/pilot but no ignition on your ReddyHeater Gas Heater, first, ensure the gas supply is turned on and the equipment shutoff valve is open. Make sure the control knob is fully pressed in while pressing the ignitor button. If there's air in the gas lines from a recent installation, continue holding down the control knob and repeat the ignition process until the air is purged. A clogged ODS/pilot can also prevent ignition; clean it or replace the assembly. Check the inlet gas pressure and replace the inlet gas regulator if damaged. Ensure the control knob is in the PILOT position. Finally, if you're using propane, check for a depleted gas supply and contact your local propane company if needed.
  • R
    Ruth PrestonAug 26, 2025
    Why won't the burner light on my ReddyHeater Gas Heater after the pilot is lit?
    • M
      marie16Aug 26, 2025
      If your ReddyHeater Gas Heater burner(s) does not light after the ODS/pilot is lit, the burner orifice may be clogged. Clean the burner orifice or replace it. Also, the burner orifice diameter might be too small, in which case you should replace it. Finally, the inlet gas pressure could be too low; contact your local gas supplier to resolve this.
  • K
    Kevin YoungAug 28, 2025
    Why does my ReddyHeater Gas Heater produce unwanted odors?
    • D
      davidfloresAug 28, 2025
      If your ReddyHeater Gas Heater is producing unwanted odors, ventilate the room and stop using odor-causing products like paints, hair spray, or glues while the heater is running. A gas leak could also be the issue; locate and correct any leaks. If you're using propane, check the fuel supply and refill the tank if it's low.
  • A
    Amy IrwinAug 30, 2025
    Why is my ReddyHeater BWH10NLMB Gas Heater burner backfiring?
    • P
      Patricia RogersAug 30, 2025
      If the burner is backfiring during combustion in your ReddyHeater Gas Heater, the burner orifice might be clogged or damaged. Clean the burner orifice or replace it. The burner itself could also be damaged, requiring replacement. Alternatively, the gas regulator might be faulty, and replacing it could solve the problem.
  • J
    Jacob ZhangSep 1, 2025
    Why does my ReddyHeater BWH10NLMB shut off while in use?
    • G
      Gregory LoveSep 2, 2025
      If your ReddyHeater Gas Heater shuts off during use (ODS operates), it could be due to insufficient fresh air. Open a window or door for ventilation. Low line pressure could also be the cause; contact your local gas supplier. Additionally, a partially clogged ODS/pilot might be the issue; clean the ODS/pilot.
  • K
    Kevin RamirezSep 4, 2025
    Why is the flame on my ReddyHeater BWH10NLMB Gas Heater high and yellow?
    • J
      jadamsSep 4, 2025
      If you notice a high yellow flame during burner combustion in your ReddyHeater Gas Heater, it could be due to insufficient air. Check the burner for dirt and debris, and clean it if necessary. A defective gas regulator could also be the cause, requiring replacement. Low inlet gas pressure might also lead to this issue, so contact your local gas supplier.
  • S
    Samantha JohnsonSep 6, 2025
    Why is there moisture on the windows when I use my ReddyHeater Gas Heater?
    • S
      Stanley OlsenSep 6, 2025
      If you notice moisture or condensation on the windows when using your ReddyHeater Gas Heater, it indicates insufficient combustion/ventilation air.
  • T
    Tiffany RodriguezSep 8, 2025
    Why do I smell gas when my ReddyHeater BWH10NLMB is turned off?
    • M
      Madeline RothSep 9, 2025
      If you smell gas even when the control knob is in the OFF position on your ReddyHeater Gas Heater, it could indicate a gas leak. Locate and correct all leaks. Alternatively, the control valve might be defective and need replacement.

ReddyHeater BWH10NLMB Specifications

General IconGeneral
ModelBWH10NLMB
CategoryGas Heater
BrandReddyHeater
Fuel TypePropane
BTU Output10, 000 BTU
Ignition TypePiezo Ignition
Safety FeaturesOverheat Shut-Off
TypePortable Forced Air Heater
ThermostatBuilt-in Adjustable Thermostat