EasyManua.ls Logo

Reefe RPS036 - Page 5

Reefe RPS036
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 5 Ascento Group Australia P: 1800 807 604 E: csv@ascento.com.au
INSTRUCTION MANUAL & WARRANTY REEFE RPS036 & RPS050
Multistage Submersible Pump
** Please leave this guide in a safe place for the owner **
PERFORMANCE DATA
CODE
MODEL
POWER
RATED
MAXIMUM
FLOAT
SWITCH
CABLE
LENGTH
OUTLET
(mm)
AMPS
P1
(kW)
P2
(kW)
FLOW
(L/min)
HEAD
(m)
FLOW
(L/min)
HEAD
(m)
12178
RPS036
3.5
0.8
0.45
40
28
100
37m
-
10m
25FBSP
12185
RPS050
4.6
1.2
0.75
50
38
100
50m
-
10m
25FBSP
13588
RPS036F
3.5
0.8
0.45
40
28
100
37m
Yes
10m
25FBSP
15582
RPS050F
4.6
1.2
0.75
50
38
100
50m
Yes
10m
25FBSP
NOTE: Performance data quoted is generally from test data and does not take into account factors in the installation such as loss of pressure and flow due to pipework & pipe-fittings & valves.
INSTALLATION GUIDELINES
Please read and follow the instructions which are to be read in conjunction with the diagrams on the earlier pages. Ensure all
installations are in compliance with any relevant Australian Standards, this is the installers responsibly. Warranty covers
manufacturing defects of the pump; it does not include faults in the installation. Note that all warranty is voided if the instructions
are not followed. Use for CLEAN FRESH WATER only.
IMPORTANT INSTALLATION & WARRANTY
CONDITIONS
1) A “First-flush-diverter” or similar device must be installed, and /or a filter screen through
which all the incoming water passes before entering the tank, to prevent debris from
entering the tank.
2) Warning: when lowering Pump into Rainwater Tank: Use the rope supplied to lower the
pump into the tank. DO NOT USE THE POWER CABLE. Using the power cable will lead to
pump failure which will not be covered by warranty, all costs will be borne by the installer.
3) Install the pump UPRIGHT in the tank. The length of the pump must be vertical, it must
not be on an angle off vertical, it must not be horizontal.