LED STATUS INDICATIONSLED STATUS INDICATIONS
LED N°LED N° COLOURCOLOUR STATESTATE INDICATIONSINDICATIONS AU S3M2 STATUSAU S3M2 STATUS
11 Green On
Barrier free,
AU S3M2 output relays energized
GUARD
22 Yellow On
Barrier free,
AU S3M2 output relays de-energized
CLEAR
33 Red On
Barrier occupied,
AU S3M2 output relays de-energized
BREAK
33 Red Flickering
System in failure,
AU S3M2 output relays de-energized
FAIL
33 Red
44 Red
Alternative
Flickering
Failure of the external relays K1 and K2,
AU S3M2 output relays de-energized
FAIL
(FAIL K1-K2)
55 Yellow On
Muting function
Sensor 1 occupied
66 Yellow On
Muting function
Sensor 2 occupied
77 Yellow On
Muting function
Sensor 3 occupied
33 Red Flickering
88 Red On
Incorrect muting sequence
AU S3M2 output relays de-energized
FAIL MUTING
11 Green On
ExternalExternal
indicatorindicator
On
Muting function active,
AU S3M2 output relays energized
MUTING