EasyManua.ls Logo

Reer VISION - User Manual

Reer VISION
8 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
7
FUNZIONAMENTO E DATI TECNICI
SEGNALAZIONI
LED COLORE STATO CONDIZIONE
1 Giallo Acceso
2 Rosso Acceso
Accensione sistema. TEST iniziale.
1 Giallo Acceso
3 Verde Acceso
Condizione di TEST
Emettitore
3 Verde Acceso Funzionamento normale
LED COLORE STATO CONDIZIONE
4 Giallo Acceso
5 Rosso Acceso
6 Rosso Acceso
Accensione sistema.
7 Verde Acceso
Area protetta libera.
5 Rosso Acceso
Area protetta occupata.
Ricevitore
4 Giallo Acceso
Segnale ricevuto debole
NOTA: Per una descrizione delle segnalazioni in caso di FAIL, consultare il paragrafo
“DIAGNOSI GUASTI” del presente manuale (pagina 23).
Figura 16
Î Nei modelli Multibeam, è presente sull’emettitore un led rosso in corrispondenza
di ogni raggio, in modo tale da consentirne una facile individuazione.

Questions and Answers

  • M
    Margaret TaylorJul 28, 2025
    What to do if Reer Lighting Equipment detects a hazardous interfering Emitter condition?
    • M
      Mr. Terry PachecoJul 28, 2025
      If your Reer Lighting Equipment detects a hazardous interfering Emitter condition, try the following steps: * Invert the positions of the Emitter and Receiver. * Move the interfering Emitter to prevent it from illuminating the Receiver. * Use opaque guards to shield the beams coming from the interfering Emitter.
  • C
    Carlos MckayAug 5, 2025
    What to do if there is overcurrent on Reer VISION Lighting Equipment outputs?
    • T
      Tina NelsonAug 5, 2025
      If you experience overcurrent on one or both outputs (OSSD) or a probable short circuit between the two outputs (OSSD) of your Reer Lighting Equipment, carefully check the connection of terminals 2 and 4 (OSSD) on the connector. If necessary, reduce the load by reducing the requested current to max. 500mA (2.2 µF). Note that these terminals can be connected directly to + 24 Vdc or to 0 Vdc or in short circuit.
  • D
    Donald ReidAug 13, 2025
    What to do if Reer VISION Lighting Equipment has internal failure relating to the static outputs?
    • M
      Matthew HuntAug 13, 2025
      Check the connection of terminals 2 and 4 (OSSD) on the connector carefully. If the problem persists, return the Reer Lighting Equipment to ReeR laboratories for repair.
  • T
    tcoxAug 19, 2025
    How to troubleshoot anomalous operation of Reer Lighting Equipment?
    • O
      Olivia RogersAug 19, 2025
      If your Reer Lighting Equipment is operating anomalously, try switching the system off and then on again to exclude any occasional electromagnetic disturbances. If the issue persists, return the equipment to ReeR laboratories for repair.

Summary

Operation and Technical Data

Emitter and Receiver Signal Status

Details LED colors, states, and conditions for both emitter and receiver units.

Troubleshooting Guide

Emitter Malfunction Diagnosis and Remedies

Provides diagnosis and remedies for emitter anomalies based on LED indicators.

Receiver Malfunction Diagnosis and Remedies

Provides diagnosis and remedies for receiver anomalies based on LED indicators.

Reer VISION Specifications

General IconGeneral
BrandReer
ModelVISION
CategoryLighting Equipment
LanguageEnglish

Related product manuals