REGAL GAS DETECTOR
Series 3000
The REGAL Series 3000 Gas Detector (Chlorine or Sulfur
Dioxide) is a very important accessory item that should
be part of ALL Regal Gas Feed System installations.
The REGAL Series 3000 Gas Detector is a safety device
that is as important as a gas mask or self contained
breathing apparatus. It should not be deleted from the
system solely on the basis that current regulations in
a given geographical area do not specifically require
this item.
A properly installed and calibrated REGAL Series 3000
Gas Detector can save lives and protect equipment and
property from the effects of these gases by providing
warning of gas leaks AS SOON AS THEY OCCUR. Properly
installed, calibrated and maintained, REGAL Series
3000 Gas Detectors can accurately sense and display
the presence of free Chlorine or free Sulfur Dioxide in
the environment at levels below those mandated by
OSHA and throughout the working life of the unit.
IMPORTANT NOTES
AND
WARNINGS
1. All software including design, appearance, algorithms and
source codes are copyrighted and owned by Chlorinator
s
I
ncorporated.
2. The entire contents of this manual MUST be read and understood
prior to installing and operating this equipment.
3. DO NOT discard this instruction manual upon completion of the
installation as this manual contains information essential to the
safe handling, operation and maintenance of this equipment.
4. Additional instruction manuals are available at nominal cost from
Chlorinators Incorporated.
5. Plastic pipe or tubing connector fittings may be broken or
damaged if tightened excessively. HAND TIGHTEN ONLY.
6. For maximum operation, the installation should be indoors so
t
hat the minimum and maximum temperature limitations as listed
in the “TECHNICAL SPECIFICATIONS” section of this manual
are not exceeded.
7. This equipment is suitable for use only with the gases specified.
DO NOT USE THIS EQUIPMENT WITH OTHER GASES. Suc
h
us
e can result in failures having hazardous consequences.
8. To insure proper and safe operation of this equipment, use only
R
EGAL parts. The use of non-REGAL parts can result in equip-
ment failures having hazardous consequences and voids t
he
REGAL warranty.
9. Maintenance should be performed by qualified personnel familiar
with this type of equipment, such as Chlorinators Incorporat
ed
t
hemselves.
10. It is essential that all external wiring be done exactly as shown
on the diagrams depicted in this manual. Incorrect wiring o
r
i
mproper grounding of this equipment WILL cause improper
operation and presents a safety hazard.
11. Field wiring MUST conform to national and local electrical
codes.
12. Disconnect power BEFORE removing the cover or servicing
this equipment.
13. ALWAYS make sure that the cover is in place and securely
fastened to prevent the entry of moisture, water or corrosive
gas
es and also to eliminate the potential for electrical shock.
14. Any equipment powered by AC line voltage presents a potential
shock hazard. Installation and servicing of this equipment
should only be attempted by qualified electronics technicians.
15. Damage to the circuit boards or internal components incurred
by drilling the enclosure for field wiring or connecting power
lines to low voltage signal terminals VOIDS the warranty.
16. Ground MUST be provided as part of the installation.