213
AVOID SERIOUS INJURY OR DEATH DUE TO
FIRE OR EXPLOSION RESULTING FROM
LEAKING FUEL!
INSPECT ENTIRE FUEL SYSTEM
AT LEAST ONCE PER YEAR.
WARNING
Fuel System
At least annually inspect all fuel system components
for loose clamps at the vent, fi ll and feed locations.
Examine each hose for signs of deterioration and
leakage. Check the fuel sender for loose bolts, nuts,
and leaks at all areas of contact. Also, inspect the
fuel tank for signs of leakage or abrasion. Tighten
all components as needed.
FUEL FEED
FUEL SENDER
ANTI-SIPHON VALVE
TYPICAL EPA FUEL TANK
FUEL VENT
FUEL FILL