Regency CLASSIC C33-2 Freestanding Gas Stove 5
SAFETY LABEL
This is a copy of the label that accompanies each
CLASSIC Freestanding Gas Stove - Propane.
We have printed a copy of the contents here for
your review. The safety label is located on the
back panel.
NOTE: Regency units are constantly being im-
proved. Check the label on the unit and if there
is a difference, the label on the unit is the correct
one.
Minimum supply pressure 12" WC/C.E.(2.85Kpa)
Manifold pressure High 11" WC/C.E.(2.61Kpa)
Manifold pressure Low 2.9" WC/C.E.(0.72Kpa)
Orifice size 52 DMS
Altitude 0-2000 ft/pi (0-610 m)
Maximum Input 33,000 BTUH (9.67Kw/h)
Minimum Input 17,000 BTUH (4.98Kw/h)
FACTORY EQUIPPED FOR PROPANE:
Model C33-LP2
GAS FIRED VENTED ROOM HEATER
This appliance must be installed in accordance
with local codes, if any; If not, follow:
ANSI Z223.1/CAN 1-B149.
Electrical Supply (115 V, 1.13 A, 60 Hz)
Not for use with solid fuel.
Optional Fan: (Part #490-917)
Listed
Certified for:
Report No.
Tested to:
: GAS FIRED VENTED ROOM HEATER
CANADA and USA
476-1345-00 (Oct. 1996)
ANSI Z21.88b-2003/CSA 2.33b-2003
FPI Fireplace Products International Ltd.
Delta, BC, Canada
Serial No.
200
Made in Canada
908-635a
DO NOT REMOVE THIS LABEL
Minimum Clearances to Combustibles
Minimum ceiling height from top of unit: 36"/914mm
Back wall
Side wall
E
A - 10"
E - 1.5"
A
A
B
Back wall
Side wall
Side wall
B-6"