    Matthew HudsonAug 16, 2025
    What to do if pressure is not correctly reached while positioning Rego-fix powRgrip PGU 9500 Power Tool?
    • E
      Eric ThorntonAug 16, 2025
      If the Rego-fix Power Tool runs on low pressure without stopping while positioning, add hydraulic oil and fix any leaks. Also, check the connection to the pressure sensor and replace the pressure sensor if needed.
  • S
    sabrina83Aug 19, 2025
    What to do if Rego-fix powRgrip PGU 9500 Power Tool shows both buttons blinking red due to not enough hydraulic oil?
    • N
      normandouglasAug 19, 2025
      If both buttons are blinking red on your Rego-fix Power Tool and the machine doesn’t reach the required pressure due to insufficient hydraulic oil, refill the hydraulic oil and repair any potential leaks. The cycle time is exceeded.
  • D
    david96Aug 22, 2025
    What to do if Rego-fix powRgrip PGU 9500 Power Tool shows both buttons blinking red because of a broken pressure sensor?
    • L
      Lisa YoungAug 22, 2025
      If both buttons are blinking red on your Rego-fix Power Tool and the machine isn’t reaching the necessary pressure because of a broken pressure sensor, check the connection to the pressure sensor and replace it. The cycle time is exceeded.
  • N
    Nicholas JohnsonAug 26, 2025
    How to reset Rego-fix powRgrip PGU 9500 Power Tool if both buttons are blinking red because the emergency stop is pushed down?
    • B
      Brandon GomezAug 26, 2025
      If both buttons are blinking red on the Rego-fix Power Tool, and the emergency stop is pushed down, unlock the emergency stop. Then, press any button to reset the error, and press any button again to reset the machine.
  • J
    jon25Aug 28, 2025
    Why Rego-fix powRgrip PGU 9500 has no function even though the push buttons light green?
    • D
      Dana GeorgeAug 28, 2025
      If your Rego-fix Power Tool has no function, even though the push buttons light green, it might be due to low voltage. Ensure the machine operates within the correct voltage range: 230V ±10% / 115V ±10% / 100V ±10%. Turn the machine off and on to reset.
  • L
    Lisa DavisAug 31, 2025
    What to do if Rego-fix Power Tool shows both buttons blinking red due to overvoltage?
    • A
      Andrew WallaceAug 31, 2025
      If both buttons are blinking red on the Rego-fix Power Tool, it could be due to overvoltage. Ensure the machine operates within the correct voltage range: 230V ±10% / 115V ±10% / 100V ± 10%. Turn the machine off and on to reset.
  • S
    smithscottSep 3, 2025
    Why is my Rego-fix powRgrip PGU 9500 Power Tool building up the wrong pressure?
    • J
      John ChapmanSep 3, 2025
      If the Rego-fix Power Tool builds up the wrong pressure, check the pressure gauge to see if the pressure is reached. The proximity switch for the clamping insert might be broken or in the wrong position.
  • J
    Jennifer AlexanderSep 6, 2025
    What to do if Rego-fix powRgrip PGU 9500 Power Tool shows both buttons blinking red because the door was opened during operation?
    • L
      Lisa BauerSep 6, 2025
      If both buttons are blinking red on the Rego-fix Power Tool because the door was opened during operation, close the door correctly. Press any button to reset the error, and then press any button again to reset the machine.
  • A
    Ashley HaleSep 9, 2025
    Why tools cannot be unclamped or clamped in Rego-fix powRgrip PGU 9500?
    • D
      David GregorySep 9, 2025
      If tools cannot be unclamped or clamped in the Rego-fix Power Tool, the tool holder might be defective or dirty.
  • A
    April DavisSep 12, 2025
    What to do if Rego-fix Power Tool shows both buttons blinking red because the door was not closed correctly?
    • R
      Regina Abbott DDSSep 12, 2025