EasyManua.ls Logo

Reliance electric AutoMax 57C430A User Manual

Default Icon
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Instruction Manual JĆ3650Ć6
AutoMax
Processor Module
M/N 57C430A
M/N 57C431
M/N 57C435
Question and Answer IconNeed help?

Do you have a question about the Reliance electric AutoMax 57C430A and is the answer not in the manual?

Reliance electric AutoMax 57C430A Specifications

General IconGeneral
CategoryControl Unit
ManufacturerReliance Electric
ModelAutoMax 57C430A
Input Voltage120/240 VAC
Frequency50/60 Hz
Humidity5 to 95% non-condensing
Weight2.5 kg
Operating Temperature0 to 60 °C
Storage Temperature-40°C to 85°C

Summary

Introduction

Additional Information

Lists related publications for correct AutoMax Processor usage.

Related Hardware and Software

Details hardware and software required for AutoMax Processor operation.

Compatibility with Earlier Versions

Explains compatibility between AutoMax Processor modules and software versions.

Mechanical and Electrical Description

Mechanical Description

Describes the physical construction and features of the Processor module.

Electrical Description

Details electrical characteristics, including watchdog timer and RS-232C circuit.

Installation

Wiring

Provides guidance on wiring to reduce electrical noise and ensure proper operation.

Initial Installation

Step-by-step instructions for installing the Processor module into the rack.

Module Replacement

Procedure for replacing an existing Processor module with a new one.

On-Board Battery Replacement

Instructions for safely replacing the module's internal battery.

Processor Module Diagnostics

Explains the power-up and run-time diagnostic procedures for the module.

Programming

Loading the Operating System

Guides on how to load the operating system (runbase) onto the Processor modules.

Accessing Processor Ports

Details how to access the module's serial ports for communication.

Programmable Tick Rate

Explains how to adjust the scan rate definition for task execution.

Restrictions

Outlines limitations and restrictions for using the Processor module in a system.

Diagnostics and Troubleshooting

The "OK" LED Is Off

Troubleshooting steps when the module's 'OK' status indicator is off.

The "BAT. OK" LED Is Off

Diagnosing issues when the battery status indicator 'BAT. OK' is off.

BUS ERROR

Interpreting and resolving bus error codes indicated on the module's LEDs.

Common Memory Module Diagnostic Failure

Troubleshooting errors related to the Common Memory module's diagnostics.

Incorrect Data

Diagnosing and resolving issues with unexpected data in application tasks.

Appendix A Technical Specifications

Appendix B Module Block Diagram

Appendix C Connecting the AutoMax Processor to the Personal Computer

Appendix D Diagnostic LED Error Codes

Appendix E Run Time LED Error Codes

Appendix F Using Modems with AutoMax Systems

Related product manuals