EasyManua.ls Logo

Remington RM2BP - User Manual

Remington RM2BP
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
769-09908 / 00 06/14
2-Cycle Backpack Blower
RM2BP
Operator’s Manual
TABLE OF CONTENTS
Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Know Your Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Oil and Fuel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Starting and Stopping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Cleaning and Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
All information, illustrations, and specifications in this manual are based
on the latest product information available at the time of printing. We
reserve the right to make changes at any time without notice.
Copyright© 2014 MTD SOUTHWEST INC, All Rights Reserved.
DO NOT RETURN THIS UNIT TO THE RETAILER. PROOF OF
PURCHASE WILL BE REQUIRED FOR WARRANTY SERVICE.
For assistance regarding the assembly, controls, operation or
maintenance of the unit, please call the Customer Support Department
at 1-866-206-2707 in the United States or 1-877-696-5533 in Canada.
Additional information about the unit can be found on our website at
www.remingtonpowertools.com.
For service, please call the Customer Support Department to obtain
a list of authorized service dealers near you. Service on this unit,
both within and after the warranty period, should only be performed
by an authorized and approved service dealer. When servicing, use
only identical replacement parts.
SAVE THESE INSTRUCTIONS
SERVICE
IMPORTANT: Read this manual thoroughly before using this product. Follow all instructions.

Questions and Answers

  • J
    Jeremy ReevesAug 2, 2025
    Why won't my Remington RM2BP engine start?
    • H
      Hayden HortonAug 2, 2025
      Several factors can prevent your Remington Blower engine from starting. It could be due to an empty fuel tank, which requires you to fill it with properly mixed fuel. Ensure you've pressed the primer bulb sufficiently, about 10 times or until fuel is visible. If the engine is flooded, move the choke lever to Position 3, squeeze the throttle control, and pull the starter rope. Old or improperly mixed fuel (over 30 days old) also causes starting issues, so drain the tank and add fresh fuel. Lastly, a fouled spark plug can be the culprit, necessitating a replacement.
  • V
    Victor WilsonAug 9, 2025
    What to do if my Remington Blower engine lacks power or stalls?
    • C
      christinejonesAug 9, 2025
      If your Remington Blower engine lacks power or stalls, consider these potential causes: old or improperly mixed fuel (over 30 days old), which means you should drain the fuel tank and add fresh, properly mixed fuel. Additionally, a dirty air filter can restrict airflow, so clean or replace it. A fouled spark plug can also cause these issues, requiring replacement.
  • M
    mdownsAug 17, 2025
    Why won't my Remington Blower engine accelerate?
    • A
      alejandro06Aug 17, 2025
      If your Remington Blower engine won't accelerate, the issue might stem from old or improperly mixed fuel (over 30 days old). In this case, drain the fuel tank and add fresh, properly mixed fuel. Another possible cause is a dirty air filter, which should be cleaned or replaced.
  • S
    Sarah DiazAug 25, 2025
    How to fix a Remington RM2BP engine that will not idle?
    • M
      Miguel SullivanAug 25, 2025
      If your Remington Blower engine won't idle, it could be due to a dirty air filter, so clean or replace it. Old or improperly mixed fuel (over 30 days old) can also cause this issue; drain the fuel tank and add fresh, properly mixed fuel. Finally, the idle speed might be incorrect, requiring adjustment.

Summary

Safety Guidelines

California Proposition 65 Warning

Warning about chemicals in the product known to cause cancer or birth defects in California.

Important Safety Instructions

Essential safety procedures to follow before operating the unit.

Assembly Instructions

Assembling the Blower Tube

Step-by-step guide for connecting the flex tube, upper, and lower blower tubes.

Oil and Fuel Handling

Fueling the Unit

Safe procedures for adding fuel to the unit, including warnings.

Mixing the Fuel

Instructions and ratios for correctly mixing fuel and 2-cycle oil.

Starting and Stopping Procedures

Starting Instructions

Detailed steps for starting the engine, including primer and choke usage.

Stopping Instructions

Procedure for safely shutting down the engine.

Maintenance Schedule and Procedures

Maintaining the Air Filter

Steps for cleaning and re-oiling the air filter for optimal performance.

Troubleshooting and Adjustments

Adjusting the Idle Speed

Procedure for adjusting the idle speed screw for smooth engine operation.

Troubleshooting Guide

Manufacturers Limited Warranty

Remington RM2BP Specifications

General IconGeneral
Nozzle TypeConcentrator
Power SourceCorded Electric
Battery IncludedNo
Charger IncludedNo
TypeHandheld

Related product manuals