8
Observe and follow the national rules and regulations for manual handling of
load weights.
2.1. Electrical connection
WARNING
Caution: Mains voltage present!
Before connecting the pipe cutting machine
or the rapid charger, check whether the voltage given on the rating plate corre-
sponds to the mains voltage. On building sites, in a wet environment, indoors
and outdoors or under similar installation conditions, only operate the pipe cutting
machine on the mains with a fault current protection switch (FI switch) which
interrupts the power supply as soon as the leakage current to earth exceeds 30
Total discharging by undervoltage
The Li-Ion batteries may not drop below a minimum voltage because otherwise
tery could be damaged by “total discharge”, see graduated charging
state display. The cells of the REMS Li-Ion battery are delivered pre-charged
%. Therefore the Li-Ion batteries must be charged before use a
recharged regularly. Failure to
observe this regulation of the cell manufacturer
can lead to damage to the Li-Ion battery by total discharging.
Total discharging due to storage
If a relatively low charged Li-Ion battery is stored, self discharging can lead
to total discharge damage of the battery after longer storage. Li-Ion batteries
must therefore be charged before storing and recharged every six months at
the latest and charged again before use.
NOTICE
Charge the battery before use. Recharge Li-Ion batteries regularly to avoid
their total discharge. The rechargeable battery will be damaged by exhaus-
REMS Cento
Height adjustable pipe rest 1, Ø 40 – 110 mm, Ø 1½ – 4"
Height adjustable pipe rest
Height adjustable pipe rest
REMS Jumbo, folding workbench 120200 120200
REMS REG 10 – 54 E, outside/inside pipe deburrer 113835
REMS REG 28 – 108, inside pipe deburrer 113840
Marking device for marking the insertion depth for fi ttings on pipes
REMS CleanM, machine cleaner 140119 140119
Stainless steel pipes, copper pipes,
Carbon steel pipes of the press fi tting systems
Ø 8 – 108 mm Ø 8 – 108 mm Ø 54 – 225 mm
Steel pipes EN 10255 (DIN 2440)
DN 6 – 100 DN 6 – 100 DN 40 – 150
Ø ⅛ – 4" Ø ⅛ – 4" 1½" – 6"
Ø 10 – 115 mm Ø 10 – 115 mm
(DIN 19522) DN 50 – 100 mm
Ø 10 – 110 mm Ø 10 – 110 mm Ø 40 – 225 mm
Ø ⅛ – 4" Ø ⅛ – 4" Ø 1¼ – 8"
Multilayer composite tubes Ø 10 – 110 mm
Welded stainless steel drainpipe/downpipe (EN 1124) Ø 40 – 110 mm
Wall thickness, copper pipes, cast pipes (SML) ≤ 4.5 mm
Wall thickness plastic/composite tubes ≤ 10.0 mm
Operating temperature range
REMS pipe cutting machines, REMS cordless pipe cutting machine -10 °C – +60 °C (14 °F – 140 °F)
-10 °C – +60 °C (14 °F – 140 °F)
0 °C – +40 °C (32 °F – 104 °F)
Rapid charger 0 °C – +40 °C (32 °F – 104 °F)Rapid charger
-10 °C – +45 °C (14 °F – 113 °F)
Cutting wheel idle speed 115 rpm 115 rpm
REMS Cento, REMS Cento RF,
230 V ~; 50 – 60 Hz; 1,200 W; 5,7 A. Fuse (mains) 10 A (B), intermittent mode S3 20% (AB 2/10 min), protective insulated, radio
interference suppressed, or 110 V ~; 50 – 60 Hz; 1,200 W; 11,4 A. Fuse (mains) 20 A, intermittent mode S3 20% (AB 2/10 min),
protective insulated, radio interference suppressed.
REMS Cento
22 V: 21.6 V ; 5.0 Ah, 21.6 V ; 9.0 Ah.
er: In
put: 100 V – 240 V ~; 50 – 60 Hz; 90 W, Output: 21.6 V
, all-insulated, interference-suppressed.
er: In
put: 100 V – 240 V ~; 50 – 60 Hz; 290 W, Output: 21.6 V
all-insulated, interference-suppressed.
: Input: 220 V – 240 V ~; 50 – 60 Hz; Output: 21.6 V
, 40 A all-insulated, interference-suppressed.
1.6. Dimensions REMS Cento REMS Cento RF
REMS Cento
L×W×H: 250×300×250 mm 250×300×250 mm
(10"×12"×14") (10"×12"×14")
without safety foot switch (without battery) 16.8 kg (37 lb) 16.8 kg (37 lb) 16.0 kg (35 lb) 37.0 kg (82 lb)
REMS battery Li-Ion 21.6 V, 5.0 Ah
REMS battery Li-Ion 21.6 V, 9.0 Ah
Acoustic pressure level L
Acoustic pressure level L
K = 3 dB(A) K = 3 dB(A) K = 3 dB(A) K = 3 dB(A)
Weighted rms value of acceleration < 2.5 m/s² < 2.5 m/s² < 2.5 m/s² < 2.5 m/s²
K = 1.5 m/s² K = 1.5 m/s² K = 1.5 m/s² K = 1.5 m/s²
The specifi ed vibration emission value was measured according to a standard test method and can be used for comparison with another device. The specifi ed vibration
emission value can also be used for an initial estimation of the cut-out.
The vibration emission value may differ from the specifi ed value during actual use of the pipe cutting machine depending on the manner in which the pipe cutting
machine is used. Depending on the actual conditions of use (intermittent mode) , it may be necessary to defi ne safety measures to protect the operator.