16
REMS V-Jet H, cleaning and preservation unit 115612
Paper roll, pack of 5 090015
Case with inserts for printer 115703
REMS Peroxi Color, dosing solution for disinfection 115605
REMS CleanH, cleaner for heating systems 115607
REMS NoCor, corrosion protection for heating systems 115608
Test strips 0 – 1000 mg/l H
Test strips 0 – 50 mg/l H
Suction/pressure hose Ø 1", 1.5 m long, with 1" hose screw fi ttings,
for fl ushing, disinfection, cleaning, preservation 115633
High-pressure hose Ø ½", 1.5 m long, with ½" hose screw fi ttings,
for pressure testing with water (REMS Multi-Push SLW) 115634
Pneumatic hose Ø 8 mm, 1.5 m long, with quick couplings NW 5 115637
Connecting hose compressor/water connections with 1" hose
screw fi tting and quick coupling NW 7.2 for pressure testing
with air (REMS Multi-Push SL/SLW) 115618
Compressed air hose pneumatic tools, 1.5 m long,
with quick couplings NW 7.2, for connecting pneumatic tools 115621
Compressed air hose Ø 8 mm, 7 m long, with quick coupling
DN 5 (plug) and G ½" hose screw fi tting, for pressure testing
with compressed air (REMS Multi-Push SL/SLW) 115667
Compressed air hose Ø 8 mm, 1.5 m long, with quick coupling
DN 5 (plug, socket) for gas testing with compressed air
(REMS Multi-Push SL/SLW) 115747
High-pressure hose Ø ½", 7 m long, with
G ½" hose screw fi ttings,
with caps, for pressure testing of pipe systems
with water (REMS Multi-Push SLW) 115661
1" double nipple, for connecting 2 suction/pressure hoses 045159
Fine fi lter with fi lter cartridge 90 µm 115609
Fine fi lter cartridge 90 µm 043054
Caps 1" with chain (REMS Multi-Push) 115619
Plugs 1" with chain (suction/pressure hoses) 115620
Plugs ½" with chain (REMS Multi-Push SL/SLW) 115624
Caps ½" with chain (high-pressure hose) 115623
Pressure gauge 6 MPa/60 bar /870 psi 115140
Fine scaled pressure gauge 1.6 MPa/16 bar/232 psi, 115045
Fine scaled pressure gauge 250 hPa/250 mbar/3.6 psi, 047069
Hood 115677
XL-Boxx system case for hoses 579600
, Machine cleaner
, Machine cleaner 140119, Machine cleaner
Device storage temperature ≥ 5°C (≥ 41 °F)
Water temperature 5°C – 35°C (41 °F – 95 °F)
Ambient temperature 5°C – 40°C (41 °F – 104 °F)
Smallest test volume approx. 10 l
Operating pressure ≤ 0.8 MPa/8 bar/116 psi
Oil separation rate oil-free
Extraction rate ≤ 230 Nl/min
Compressed air vessel volume (Fig. 1 (35)) 4.9 l
Condensation and particle fi lter 5 µm
Flushing water connections DN 25, 1"
Water pressure pipe network ≤ 1 MPa/10 bar/145 psi
Water pressure when fl ushing with compressed air ≤ 0.7 MPa/7 bar/101 psi
Pipe diameter installation ≤ DN 50, 2"
Pressure testing of drinking water installations
Pressure testing of drinking water installations
Pressure test with compressed air ≤ 0.4 MPa/4 bar/58 psi
Reading accuracy < 200 mbar 1 hPa/1 mbar/0.015 psi
Reading accuracy ≥ 200 mbar 100 hPa/0,1 bar/1.5 psi
Pressure test with water ≤ 1.8 MPa/18 ba r/261 psi
Reading accuracy 0.02 MPa/0.2 bar/3 psi
Pressure testing of gas installations
Pressure testing of gas installations
Pressure test with compressed air ≤ 0.3 MPa/3 bar/44 psi
Reading accuracy < 200 mbar 10 Pa/0,1 mbar/0.002 psi
Reading accuracy ≥ 200 mbar 100 hPa/0,1 bar/1.5 psi
1.4 Electrical/electronic data
Type of protection terminal box IP 44
Type of protection device, motor IP 20
Operating mode (continuous operation) S 1
Data transfer with USB stick USB port
Printer, battery NiMH 6 V
Charger printer Input 100 – 240 V~; 50 – 60 Hz; 0.15 A
Paper roll printer B × Ø 57 × ≤ 33 mm
REMS Multi-Push S 32.0 kg (71 lb)
REMS Multi-Push SL 36.7 kg (81 lb)
REMS Multi-Push SLW 39.0 kg (86 lb)
= 73 dB(A); L
WA
= 73 dB(A); L
= 92 dB(A); K = ± 1 dB(A)
Transport weights above 35 kg must be carried by at least 2 persons.
Compressed air line compressor/pressure vessel (47) gets hot and can cause
NOTICE
REMS Multi-Push is not intended/suitable for permanent connection to the
installation. Disconnect all hoses from the installation after completing the work.
REMS Multi-Push may not be operated unattended.
2.1 Electrical connection
WARNING
Caution: Mains voltage present!
Before connecting the electronic fl ushing
and pressure testing unit, check whether the voltage given on the rating plate
corresponds to the mains voltage. Only use sockets/extension leads with a
ct.
Check the function of the PRCD fault current circuit breaker
Th
e function of the PRCD fault current circuit breaker (Fig. 1 (1)) must be
checked every time before start-up and before beginning work:
1. Plug the mains plug into the socket.
2. Press the RESET button (2), the PRCD control lamp (Fig. 1 (39)) lights red
3. Pull out the mains plug, the PRCD control lamp (39) must go out.
4. Plug the mains plug back into the socket.
5. Press the RESET button (2), the PRCD control lamp (39) lights red (oper-
6. Press the TEST button (3), the PRCD control lamp (39) must go out.
7. Press the RESET button (2) again, the PRCD control lamp (39) lights red.
The control lamp (Fig. 2 (5)) lights green. REMS Multi-Push is ready for
operation after about 10 s.
WARNING
If the described functions of the PRCD fault current circuit breaker (Fig. 1 (1))
are not fulfi lled, the device may not be used. There is a danger of electric shock.
The PRCD fault current circuit breaker tests the connected device, not the
installation before the socket nor interconnected extension leads or cable reels.
On building sites, in a wet environment, indoors and outdoors or under similar
installation conditions, only operate the electronic fl ushing and pressure testing
unit on the mains with a fault current protection switch (FI switch) which interrupts
the power supply as soon as the leakage current to earth exceeds 30 mA for
200 ms. A cable cross-section that corresponds to the power of the electronic
fl ushing and pressure testing unit must be selected when using an extension lead.
2.2 Menu structure and on-screen displays
Press the On/Off button on the input and control unit's operating panel (Fig. 2
(4)) for approx. 2 s, then release it. REMS Multi-Push is switched on and the
compressor switches on. The screen (6) is illuminated and the Logo REMS
Multi-Push logo appears followed by the Start menu:
REMS Multi-Push S: REMS Multi-Push SL/SLW:
The screen display contains a maximum 5 lines with 20 characters each. Lines
with defaults or test values are displayed
ical formula symbols, a uniform verbal abbreviation and the value of the test
criterion in the sub-routines. These have the following meanings:
p refer bar xxx reference test pressure bar
p refer mbar xxx reference test pressure mbar
p actual bar xxx actual test pressure bar
p actual mbar xxx actual test pressure mbar
p diff bar xxx differential test pressure bar
p diff mbar xxx differential test pressure mbar
t stabi min xxx stabilisation/wait time min
t test min xxx test time min
Δ > 10K difference >10°C (10 Kelvin) water/environment
PfS press fi tting system (ZVSHK)
P+M load test plastic + metal
O min fl ushing/disinfecting/cleaning/preservation time