Table of Contents

Questions and Answers

  • B
    Benjamin ReidAug 13, 2025
    Why is my Reno 300/40 Air Compressor compressing air even though it has reached the working pressure?
    • B
      Brianna GarrettAug 13, 2025
      If your Reno Air Compressor continues to compress air despite reaching the set working pressure, the pressure switch may be covered with verdigris. The suggested solution is to replace the pressure switch.
  • L
    lawrencerobinAug 17, 2025
    Why does air continuously leak from the pressure switch when my Reno Air Compressor is stopped?
    • J
      Jason MoraAug 17, 2025
      If air continuously leaks from the pressure switch of your Reno Air Compressor when it's stopped, it could be due to dirt in the bypass valve. Try cleaning the bypass valve or replacing the rubber fitting in the bypass valve.
  • W
    williamsnicoleAug 20, 2025
    What to do if my Reno 300/40 starts and stops frequently?
    • D
      David KingAug 21, 2025
      If your Reno Air Compressor starts and stops frequently, it might be because overdimensioned air tools are being used. Check the air consumption of your tools.
  • J
    jsmithAug 25, 2025
    Why is all air drifting out through the pressure switch after air compression in my Reno 300/40?
    • P
      Paul PowellAug 26, 2025
      If all the air drifts out through the pressure switch after air compression in your Reno Air Compressor, it's likely that dirt is stuck in the bypass valve, or the black rubber plug is defective. The suggested solution is to clean the bypass valve or replace the rubber plug.
  • J
    jonathangarciaAug 28, 2025
    Why is my Reno Air Compressor very noisy?
    • L
      Lee WagnerAug 28, 2025
      If your Reno Air Compressor is excessively noisy, it may be due to using the wrong type of oil. Ensure you are using synthetic compressor oil only. It might be necessary to replace the pump unit.
  • T
    Tom HornSep 1, 2025
    What to do if my Reno 300/40 Air Compressor does not work 100 %?
    • D
      Deanna BallSep 1, 2025
      If your Reno Air Compressor isn't working at full capacity, a possible cause is a missing phase in the power supply. Open the electricity box on top of the motor and check that all wires are properly connected.
  • B
    Bryan JohnsonSep 5, 2025
    Why is the safety valve activated on my Reno 300/40 Air Compressor even though max pressure has not been reached?
    • J
      Jeffrey MeyerSep 5, 2025
      If the safety valve on your Reno Air Compressor activates before reaching the maximum pressure, the safety valve may be defective. Replace the safety valve.
  • L
    Logan BaileySep 8, 2025
    How to fix a Reno 300/40 Air Compressor that leaks oil?
    • B
      Brian MooreSep 8, 2025
      If your Reno Air Compressor is leaking oil, the oil level might be too high. Remove oil through the plug until the oil glass is half full.

Reno 300/40 Specifications

General IconGeneral
BrandReno
Model300/40
CategoryAir Compressor
LanguageEnglish