7
Azore
®
3 • Wind class
In accordance with the quality of the product, Azore with closed blades can withstand wind speeds of 120
km/h (>11 BFT).
Note: wind categories are indicated here in accordance with the standard DIN 13561:2014.
Wind class
Wind force
(on Beaufort scale)
Wind speed
Class 0 Product not tested/not in compliance
Class 1 4 bft 20 - 28 kph
Class 2 5 bft 29 - 38 kph
Class 3 6 bft 39 - 49 kph
Class 4 7 bft 50 - 61 kph
Class 5 8 bft 62 - 74 kph
Class 6 9 bft 75 - 88 kph
10 bft 89 -102 kph
11 bft 103 - 117 kph
12 bft > 117 kph
To maintain a stable construction, the blades of Azore should be closed at wind speeds higher than 50km/h.
Azore is to be installed only at ground level.
3 • Windklasse
Entsprechend der Qualität des Produkts kann Azore mit Lamellen in geschlossenem Zustand Windgeschwin-
digkeiten von 120 km/h (>11 Bft) widerstehen.
Zur Information hier die Windklassen laut Norm DIN 13561:2014.
Windklasse
Windstärke
(nach Beaufort-Skala)
Windgeschwindigkeit
Klasse 0 Produkt nicht geprüft oder nicht konform
Klasse 1 4 bft 20 - 28 km/h
Klasse 2 5 bft 29 - 38 km/h
Klasse 3 6 bft 39 - 49 km/h
Klasse 4 7 bft 50 - 61 km/h
Klasse 5 8 bft 62 - 74 km/h
Klasse 6 9 bft 75 - 88 km/h
10 bft 89 - 102 km/h
11 bft 103 - 117 km/h
12 bft > 117 km/h
Für eine stabilere Konstruktion müssen Sie die Lamellen von Azore bei Windgeschwindigkeiten über
50km/h schließen.
Azore wird nur im Erdgeschoss montiert.