R32346912-001
Braukmann
Miniplus FK06/FK06-AAM
Installation instructions Einbauanleitung Instrukcja montażu Руководство по установке
Filter Combination
Filterkombination
Zespołu Filtracyjnego
Комбинированный фильтр

Questions and Answers

  • J
    Jessica ClarkAug 11, 2025
    Why is there too little or no water pressure in my resideo Braukmann Miniplus FK06 Water Filtration Systems?
    • N
      Nicole GillespieAug 11, 2025
      If you're experiencing too little or no water pressure with your Resideo Water Filtration System, here are a few things to check: * Ensure that the shut-off valves upstream or downstream from the filter are fully open. If they aren't, fully open them. * Make sure the filter combination is set to the desired outlet pressure. If not, set the outlet pressure appropriately. * Inspect the filter mesh for dirt. If it's dirty, clean or replace the filter. * Verify that the filter is fitted in the correct flow direction, paying attention to the arrow on the housing. If it's not, fit the filter in the correct flow direction.
  • J
    Joel FlemingAug 17, 2025
    What to do if the outlet pressure set does not remain constant in Resideo Water Filtration Systems?
    • B
      Brittany WaltersAug 17, 2025
      If the outlet pressure set on your Resideo Water Filtration System does not remain constant, consider the following: 1. Check the filter mesh for dirt. If it's dirty, clean or replace it. 2. Inspect the valve insert, sealing ring, or edge of the nozzle for contamination or wear. If any of these components are contaminated or worn, replace the valve insert. 3. Examine for rising pressure on the outlet, possibly due to a boiler. Check the check valve, safety group, etc.
  • A
    Ashley MyersAug 23, 2025
    How to fix water escaping from the spring bonnet in resideo Braukmann Miniplus FK06 Water Filtration Systems?
    • B
      Barbara Deleon DDSAug 23, 2025
      If water is escaping from the spring bonnet of your Resideo Water Filtration System, it indicates that the diaphragm in the valve insert is faulty. Replace the valve insert to resolve this issue.
  • R
    Richard StantonAug 29, 2025
    Why does the outlet pressure set not remain constant in resideo Braukmann Miniplus FK06 Water Filtration Systems?
    • J
      James SnyderAug 29, 2025
      If the outlet pressure set on your Resideo Water Filtration System doesn't remain constant, it could be due to a dirty filter mesh, which requires replacement with a completely new one. Alternatively, the valve insert, sealing ring, or edge of the nozzle might be contaminated or worn, necessitating replacement of the valve insert. Also, rising pressure on the outlet, such as in a boiler, might be the cause, so you should check the check valve and safety group.
  • B
    baileythompsonSep 4, 2025
    What to do if water is escaping from the spring bonnet of resideo Braukmann Miniplus FK06?
    • A
      ariel64Sep 4, 2025
      If water is escaping from the spring bonnet of your Resideo Water Filtration System, it's likely that the diaphragm in the valve insert is faulty. Replace the valve insert to resolve this issue.

resideo Braukmann Miniplus FK06 Specifications

General IconGeneral
CategoryWater Filtration Systems
Maximum operating pressure16 bar
Connection size1/2" - 1"
BrandResideo
ModelMiniplus FK06
MediumWater
Pressure reducing valve setting range1.5 - 6 bar
Dimensions (H x W x D)varies by model
Weightvaries by model
CertificationDVGW
TypeFilter with pressure reducer
Filtration TechnologyFine mesh filter