Regulatory
UL SYSTEM REQUIREMENTS
Control Unit, consisting of:
Base Panel: RE6100 series
Backup Battery: RE029 (6V, 2.5Ah, NiMH)
Power Supply: RE012-6 (In: 100-240VAC; Out: 12VDC, 1A)
PINPad (RE652) or HeliPad (RE656), connected wirelessly
Ethernet connection native to base panel or Cellular module
(RE928RxS, RE928RxV, or RE927RxA)
Compatible ETL listed signal initiating devices:
RE612 Smoke Detector
RE613 CO Detector
RE601 Door/Window Sensor
RE622 NanoMax Door/Window Sensor
RE610P Motion Detector
Optional devices, not ETL listed:
Any of a wide array of CryptiX sensors.
UL1023 Household Burglar Alarm System:
Control Unit
At least one burglary signal initiating device
Entry delay: 45 seconds or less
Exit delay: 60 seconds or less
Sensor supervisory: 24 hours or less
Panel status volume: on
Panel siren: on
Auto force arm: on
Siren timeout: 4 minutes or more
ORD-C1023-1974 Canadian Household Burglar Alarm System:
Control Unit and installation as described for UL1023
Power supply: RE012-6, Do NOT secure with a receptacle
securing screw. Ne pas se connecter Helix à une prise
contrôlée par un interrupteur.
Siren timeout: 6 minutes or more
UL985 Household Fire Warning System:
Control Unit
At least one smoke signal-initiating device enrolled into
“Fire” zone prole.
Smoke supervision: on
Panel siren: on
Siren timeout: 4 minutes or more
Panel status volume: on
ULC-S545-M89 Canadian Household Fire Warning System:
Control Unit and installation as described for UL985
Power supply: RE012-6, Do NOT secure with a receptacle
securing screw. Ne pas se connecter Helix à une prise
contrôlée par un interrupteur.
Siren timeout: 6 minutes or more
Central Station Communicator Requirement is at least one of:
UL1610 Central Station Burglar Alarm System: Ethernet
connection native to base panel
-OR-
UL1635 Digital Alarm Communicator System: Cellular
module RE928RSS, RE928RSV, or RE927RSA
RF supervision: 4 hours
Communication interface supervision: on
Entry delay plus reporting delay must not exceed 60
seconds.
Reporting delay is 30 seconds.
Network Equipment:
Use a UL 60950-1 listed broadband router/modem for the
10/100 Ethernet port or Wi-Fi connection
CE SYSTEM REQUIREMENTS
Access Levels:
Access Level 1: Person with no access to
the security system features.
Access Level 2: Regular users with access
to all features on the security system with
a code.
Access Level 3: Master and Alarm
company users that can do everything a
level 2 user can do and also change system
settings (e.g. add, modify, or delete users).
Access Level 4: Manufacturer of
equipment access. Typically used for
system updates.
User Codes:
Four or more invalid code attempts will
disable the interface and trigger a tamper
condition.
There are 10,000 unique 4-digit PIN codes.
There are 16,777,215 unique identication
codes for logical keys (Keyfobs).
Priority of Indicators:
Fire alarm
CO alarm
Panic alarm
Burglary alarm
Tamper alarm
Auxiliary alarm
Freeze alarm
Heat alarm
Water alarm
Tamper indication
Fault indication
Ancillary Control Devices:
Up to 8 PINPads (RE652)
Up to 16 HeliPads (RE656) and/or mobile
devices.
PINPads and HeliPads can issue panic
alarms.