EasyManua.ls Logo

RESPICARE OXY 4 6RDP4XLO10W7L - User Manual

Default Icon
5 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
OXY 4
• Dual UV Oxidizing lamp
• Tandem Feature for Multiple Units
• Programmable LCD for Contact details • Large Surface area for Active Oxidation
e 40
Ultra Violet Advanced Air Treatment System
• Helps Kill, Oxidize & Sterilize
• 9” & 16” Models
• Multi Voltage - Auto Sensing Ballast
• UVC “Smart Light” monitor
• High Temp “Attic” model - 220Fº (104Cº)
Features
Dimensions:
Electrical:
Weight:
Humidity:
Lamp Life
Power Requir d 24VA
Specifications
Dimensions:
Electrical:
Weight:
Humidity:
Lamp Life
Power Required 24VA :
OXY 4 Air Sterilizer
Replacement Lamps
6 ½ x 6 ½ x
Less than 4 lbs.
Water - resistant lamp
9000 hours
6 ½ x 6 ½ x 9" & 16"
24 to 120 VAC
*
Less than 4 lbs.
Water - resistant lamp
9000 hours
40 VA Transformer
*24Volt up to 18 watts
*120Volt for 36 watt models
• Whole Home Purification
TM
Power supply can cause electrical shock. Be
s
ure the UV power supply is disconnecte
d
b
efore installaon begins.
D
o not open the ballast unit as it is designate
d
t
o be installed as one piece. There are no
s
ervice components inside.
U
V light may aect plascs in the heang and
c
ooling system. Select a locaon that reduces
l
amp exposure to plasc components that ar
e
n
ot UV resistant.
D
o not touch glass without gloves. Keep lam
p
s
urface clean.
Lamps contain small amounts of mercury. If
l
amp breakage occurs, clean area and dispos
e
w
ith care.
T
o minimize the risk of UV exposure to skin an
d
e
yes, only power the lamp when th
e
i
nstallaon is complete. Lamp illuminaon i
s
c
onrmed by the UV safety port window.
D
isconnect power before all lamp change-out
s
o
r servicing. There are several disconnects. W
e
r
ecommend completely disconnecng al
l
p
ower from electrical power supply.
LED “SMART LIGHT” MONITOR
PROGRAMMABLE LCD OPTION
USB PROGRAMMING PORT
EXTENDED SURFACE AREA
WITH CATALYTIC REACTIONS
FOR ADVANCED PLASMA
OXIDIZERS
6RDOXY-inst1
1-866-876-8044 • 416-615-0214 • www.respicaire.com
Model: 6RDP4X(L)O10W7L REPLACEMENT LAMP: 6RBUVO10W7L
Model: 6RDP4X(L)O18W9L REPLACEMENT LAMP: 6RBUVO18W9L
Model: 6RDP4X(L)O36W16L REPLACEMENT LAMP: 6RBUVO36W16L
Model: 6RDP4X(L)O10W7L REPLACEMENT PCO TRAY Oxy 4: 6RS4X9L
Model: 6RDP4X(L)O18W9L REPLACEMENT PCO TRAY Oxy 4: 6RS4X9L
Model: 6RDP4X(L)O36W16L REPLACEMENT PCO TRAY Oxy 4: 6RS4X16L
Question and Answer IconNeed help?

Do you have a question about the RESPICARE OXY 4 6RDP4XLO10W7L and is the answer not in the manual?

Summary

Oxy 4 Air Sterilizer Features

Core Sterilization Capabilities

Helps kill, oxidize, and sterilize air using advanced technology.

Dual UV Oxidizing Lamp

Features a dual UV oxidizing lamp for enhanced air treatment.

Model Sizes

Available in 9-inch and 16-inch model configurations.

Whole Home Purification

Designed to provide air purification for an entire home.

Programmable LCD Functionality

Includes a programmable LCD for managing contact details.

UVC Smart Light Monitoring

Equipped with a UVC 'Smart Light' monitor for status indication.

Multi-Voltage Auto-Sensing Ballast

Features a multi-voltage ballast that automatically senses input voltage.

High Temperature Attic Model

Offers a high-temperature 'Attic' model suitable for 220F environments.

Tandem Unit Connectivity

Supports a tandem feature allowing multiple units to be connected.

Large Surface Area for Oxidation

Provides a large surface area for effective active oxidation.

Safety Precautions and Warnings

Electrical Shock Hazard

Disconnect power supply before installation to prevent electrical shock.

Ballast Unit Integrity

Do not open the ballast unit as it is a sealed, single-piece component.

Mercury Lamp Handling

Handle mercury-containing lamps with care and dispose of broken lamps properly.

UV Exposure Minimization

Power lamp only after complete installation to minimize UV exposure risk.

Plastic Material Compatibility

Select locations to reduce lamp exposure to UV-sensitive plastic components.

Lamp Handling and Maintenance

Handle glass lamps with gloves and ensure lamp surfaces are kept clean.

Service Power Disconnection

Completely disconnect all power from the electrical supply before servicing.

Product Specifications

Dimensions and Weight

Unit dimensions are 6½"x6½"x9" or 16"; weight is less than 4 lbs.

Electrical Requirements

Operates on 24-120 VAC, with power requirement of 24VA (40 VA transformer).

Lamp Life and Power Consumption

Lamp life is 9000 hours; power is 18W for 24V and 36W for 120V models.

Replacement Parts Information

Replacement Lamp Models

Lists various replacement lamp models for the Oxy 4 unit.

PCO Tray Models

Identifies compatible PCO Tray models for Oxy 4 units.

Installation Guide

Step 1: Template Placement

Use rubber template for installation location and mount it by peeling backing.

Step 2: Duct Access Hole

Cut the required access hole in the duct as indicated.

Step 3: Base Plate Mounting

Mount the base plate securely to the duct using four screws.

Step 4: Unit Assembly and Locking

Slide assembly into base plate, depressing locking tabs to secure.

Electrical Connections

120 Volt Connection Procedure

Connect to 120V power and verify the UVC LED light monitor is illuminated.

24 VAC Connection Procedure

Connect 24VAC power (up to 18W) using a supplementary 40VA transformer.

Tandem Installation (120 Volt Units)

Removing Tandem Access Door

Remove the tandem access door located on the right side of the unit.

Linking Multiple Units

Connect units in series, then power the main unit. Verify all LED monitors.

LCD Programming Guide

LCD Screen Content Rotation

LCD cycles through Respicaire logo, service days, and dealer contact info.

Programming Dealer Contact Info

Insert USB memory stick to program dealer/contractor contact information.

Character Entry Navigation

Use joystick to navigate and select characters for screen programming.

Advanced LCD Programming

Editing Text Content

Edit information with a maximum of 16 characters per line across 4 lines.

Saving Programmed Information

Remove memory stick to save data; it can be reused for future installations.

Resetting Notification Timer

Press center and left buttons together for 5 seconds to reset the notification timer.

Warranty and Medical Information

Limited Warranty Coverage

Provides a 5-year residential and 1-year commercial limited warranty.

Warranty Claim Procedure

Contact installer or Respicaire with proof of purchase for warranty claims.

Medical Insurance and Tax Deductibility

Air cleaners may be medically covered or tax deductible if prescribed by a physician.

Overview

OXY 4™ Air Sterilizer: Ultra Violet Advanced Air Treatment System

The OXY 4™ Air Sterilizer is an advanced air treatment system designed to purify indoor air through a combination of ultraviolet (UV) light and catalytic reactions. This device utilizes an extended surface area to maximize the effectiveness of its advanced plasma oxidizers, aiming to kill, oxidize, and sterilize airborne contaminants. The system is engineered for whole-home purification, making it suitable for integration into existing heating and cooling systems.

Function Description

At its core, the OXY 4™ Air Sterilizer employs dual UV oxidizing lamps, which are central to its air purification capabilities. These lamps emit ultraviolet-C (UVC) light, a known germicidal wavelength that effectively neutralizes bacteria, viruses, and mold spores by disrupting their DNA. In addition to direct germicidal action, the UV light interacts with the extended surface area, initiating catalytic reactions that generate advanced plasma oxidizers. These oxidizers are highly reactive molecules that break down volatile organic compounds (VOCs), odors, and other airborne pollutants into harmless substances like carbon dioxide and water vapor. This dual-action approach ensures comprehensive air treatment, addressing both biological contaminants and chemical pollutants.

The system is designed to be installed within the ductwork of a home's HVAC system, allowing it to treat the air as it circulates throughout the living space. This strategic placement ensures that all air passing through the system is exposed to the purifying effects of the UV lamps and plasma oxidizers, providing continuous and consistent air quality improvement. The device is available in different models, accommodating various installation requirements and purification needs.

Usage Features

The OXY 4™ Air Sterilizer is equipped with several user-friendly features that enhance its functionality and ease of operation. A key feature is the UVC "Smart Light" monitor, which provides a visual indication of the lamp's operational status. This LED monitor allows users to quickly ascertain if the internal UVC lamp is functioning correctly, ensuring continuous purification. For more detailed information and control, an optional programmable LCD display is available. This LCD screen can show various information, including a Respicaire logo, the number of days remaining before service is due, and customizable dealer/contractor contact information.

The device incorporates a multi-voltage, auto-sensing ballast, which simplifies installation by automatically adapting to different electrical inputs. This flexibility makes the OXY 4™ suitable for a wider range of residential applications. For homes with specific environmental conditions, a high-temperature "Attic" model is available, designed to withstand temperatures up to 220°F (104°C), ensuring reliable performance even in challenging environments.

For larger homes or commercial spaces requiring more extensive air treatment, the OXY 4™ supports a tandem feature, allowing multiple units to be connected. This scalability ensures that the system can effectively purify air in spaces of varying sizes. The large surface area for active oxidation further enhances the device's efficiency in breaking down pollutants.

Installation is designed to be straightforward. The process involves using a rubber template to mark the installation location, cutting an access hole in the duct, mounting a base plate with screws, and then sliding the main assembly into place, securing it with locking tabs. Electrical connection options include both 120-volt and 24-volt AC power, with specific instructions for each to ensure proper setup. For 24-volt installations, a supplementary 40VA transformer is required for models up to 18 watts, while 36-watt models necessitate a 120-volt connection. The tandem installation feature, exclusively for 120-volt systems, allows up to four units to be connected in series using a provided power cord, simplifying wiring for multi-unit setups.

The programmable LCD option offers a unique customization feature. Users can program the dealer/contractor contact information screen using a memory stick inserted into a USB port. A joystick control allows navigation through characters on an alphanumeric screen to input desired text, providing a personalized service reminder for homeowners. This feature ensures that homeowners have easy access to their service provider's contact details when maintenance is required. The system also includes a reset notification timer, which can be activated by depressing specific buttons on the device for a set duration.

Maintenance Features

Maintaining the OXY 4™ Air Sterilizer is crucial for its continued effectiveness and longevity. The device is designed with features that facilitate maintenance and ensure optimal performance. The primary maintenance task involves replacing the UV oxidizing lamps, which have a specified operational life. The programmable LCD display plays a vital role in this aspect by showing the "number of days remaining before service," prompting users when it's time for a lamp replacement. This proactive notification helps prevent a decline in purification efficiency due to aged lamps.

The UVC "Smart Light" monitor, while primarily a usage feature, also serves as a maintenance indicator. If the LED light is not illuminated, it signals that the internal UVC lamp is not operating, indicating a need for inspection or replacement. This immediate visual feedback is essential for troubleshooting and ensuring the system is actively purifying the air.

When replacing lamps or performing any servicing, safety is paramount. The manual explicitly warns users to disconnect power before any lamp change-outs or servicing, emphasizing that there are several disconnects and recommending complete power disconnection from the electrical supply. This precaution is critical to prevent electrical shock and UV exposure.

The design of the unit, with its base plate and sliding assembly, suggests that lamp replacement is intended to be a relatively straightforward process, likely involving accessing the internal components after the main assembly is disengaged from the base plate. The manual also advises against opening the ballast unit, as it is designed as a sealed component with no user-serviceable parts inside.

Furthermore, the manual provides warnings regarding the handling of lamps, noting that they contain small amounts of mercury and require careful disposal if breakage occurs. It also advises against touching the glass of the lamps without gloves to keep the lamp surface clean, as oils from skin can reduce UV output.

The programmable LCD's ability to store dealer/contractor contact information is a practical maintenance feature, as it provides homeowners with immediate access to professional assistance for servicing or lamp replacements. This ensures that maintenance can be performed by qualified personnel, adhering to recommended procedures and using appropriate replacement parts. The memory stick used for programming can also be utilized to upload contact information to new UV modules, streamlining setup for subsequent installations.

RESPICARE OXY 4 6RDP4XLO10W7L Specifications

General IconGeneral
ModelOXY 4
TypePortable
Power SupplyAC/DC, Battery
Battery Life4-5 hours
Noise Level45 dB