PROFESSIONAL
alarm systems
RE5000S
professional
Solar
Wireless
Intruder
Alarm
System
includes:
1 x Solar Wireless
Siren and Strobe
1 x Control Unit
1 x Passive Infra
Red Detector
1 x Magnetic Contact
Detector
1 x Remote Control
1 x Power Supply
INSTALLATION & OPERATING
HANDBOOK
INSTALLATION & OPERATING
HANDBOOK
Question and Answer IconNeed help?

Do you have a question about the Response Alarms RE5000S and is the answer not in the manual?

Response Alarms RE5000S Specifications

General IconGeneral
BrandResponse Alarms
ModelRE5000S
CategorySecurity System
LanguageEnglish

Summary

Foreword

Safety Warnings

Provides crucial safety advice and precautions to be followed before commencing installation.

System Security

Discusses system operation, access codes, and recommendations for physical security.

Tools and Equipment Required

Lists the necessary tools and equipment for installing the alarm system.

Introduction & Overview

Extending the RE5000S System

Details optional accessories available to enhance the alarm system's capabilities and protection.

Planning and Extending Your Wireless Alarm System

Part Arm

Explains how to arm specific zones while leaving others inactive for partial security.

Planning Your Installation

Guidance on assessing security needs and planning the system's layout and zoning.

Control Unit

Indicators and Keypad

Describes the function of LEDs, buttons, and the keypad on the control unit.

Location

Provides recommendations for selecting an optimal and secure placement for the control unit.

Installation

Step-by-step instructions for mounting, wiring, and connecting the control unit.

Back-up Battery

Explains the purpose, installation, and function of the control unit's backup battery.

Remote Control(s)

Setting the Control Unit House Code

Guides on programming the system's unique identification code for communication.

System Zoning

Setting the Control Unit to Test Mode

Instructions for activating and using the system's test mode for setup verification.

Wireless Passive Infra Red Detector(s)

Setting the Wireless Passive Infra Red Detector(s)

Procedure for setting the detector's house code and zone assignment.

Mounting the Wireless Passive Infra Red Detector(s)

Detailed steps for physically installing the PIR detector, including corner mounting.

Testing the Wireless Passive Infra Red Detector(s)

How to verify the detector's operation and radio range during installation.

Fitting the Standard Magnetic Contact Detector(s)

Installing and Setting the External Solar Wireless Siren & Strobe

Location

Guidance on selecting an optimal, visible, and secure mounting position for the siren.

Installation

Steps for physically mounting the solar siren and strobe unit to an external wall.

Settings

Configuration options including Siren Code and Alarm Duration dip switch settings.

Programmable Functions

1. House Code

Setting the system's unique identification code for detector and remote communication.

2. Instant/Delay Zone

Configuring zones for immediate alarm activation or a timed entry delay.

3. Exit Delay Time

Setting the duration before the system fully arms after the exit period.

4. Alarm Autostop Time

Defining the maximum duration the alarm siren will sound after activation.

5. Main User Access Code

Establishing the primary four-digit code for system operation and programming.

6. Door-Chime Zone

Enabling chime alerts for specific zones, typically magnetic contact detectors on doors.

7. Entry Delay Time

Setting the time allowed to disarm the system upon triggering an entry delay zone.

8. Part Arm Zone Omit

Selecting which zones are active or omitted when the system is set to 'Part Arm'.

9. Exit Delay Tone

Choosing audible feedback (tone or silent) during the exit delay period.

10. Quick Arm/Part Arm

Enabling fast arming and part-arming without needing to enter an access code.

11. Jamming Detection System

Configuring the system to detect and alert on radio jamming attempts.

12. Siren Code (and Optional Medical Alert Pendant Code)

Programming codes to link the control unit with external sirens and medical alert pendants.

13. Second User Access Code

Setting a secondary four-digit code for limited system access (arming/disarming only).

External Connections

Operating Instructions

Fully Arming the System

Procedure for arming the system completely when leaving the premises.

Part Arming the System

How to arm the system while remaining on the premises, allowing access to omitted zones.

Disarming the System

Steps to deactivate the alarm upon entering through an entry delay zone.

Disarming After an Intrusion

Procedure to cancel an active alarm and reset the system after an event.

Personal Attack, Medical and Fire Alarm

Instructions for initiating emergency alerts for personal attack, medical, or fire events.

Battery Monitoring

How the system monitors and indicates low battery conditions in detectors and peripherals.

Testing the System

Guidelines for regularly testing the alarm system's functionality and components.

Maintenance

Control Unit

Cleaning and care instructions for the main control unit, avoiding solvents.

Solar Siren & Strobe

Maintenance procedures for the external siren, including solar panel cleaning.

Rechargeable Batteries

Information on the lifespan, charging, and responsible disposal of rechargeable batteries.

Detectors & Remote Control

Guidance on replacing batteries in detectors and remote control units.

Trouble Shooting

Control Unit will not arm.

Troubleshooting steps for when the system fails to arm, indicated by three bleeps.

Detection Zone has been triggered but no alarm is sounding

Diagnosing issues when a zone is triggered but no alarm sounds, e.g., entry delay.

Control Unit 'Low Battery' light flashing, Zone LED(s) flashing and control unit bleeping every 60 seconds

Resolving low battery indications for detectors and the control unit itself.

Full Alarm Occurs when alarm has not been activated by an intruder

Investigating and resolving false alarms or unintended full alarm activations.

Control Unit not working. Mains light is off.

Troubleshooting steps for power-related issues where the control unit is unresponsive.

Control Unit will not function (Sirens are sounding)

Addressing situations where sirens sound without an apparent trigger or system fault.

Control Unit not accepting access code(s).

Solutions for problems with the control unit keypad not recognizing entered access codes.

Control Unit emits two-tone chime when detectors are triggered.

Diagnosing chime activation for detectors, potentially related to Door-Chime settings.

Control Unit not responding to detectors.

Troubleshooting communication failures between detectors and the control unit.

Solar Siren and Strobe sounding but no alarm at Control Unit.

Addressing issues where the external siren activates but the control unit does not register an alarm.

Solar Siren and Strobe does not operate when system activated.

Fixing problems where the external siren and strobe fail to activate during an alarm event.

No response from Passive Infra Red Detector

Troubleshooting communication failures with the passive infra red motion detectors.

Passive Infra Red Detector not detecting a person's movement

Diagnosing PIR sensor issues, including sensitivity and mounting height.

Passive Infra Red Detector flashes when you walk past it

Identifying potential issues with PIR detectors, such as low battery or environmental factors.

Passive Infra Red Detector false alarming

Steps to prevent unwanted triggers from PIR detectors due to heat or movement.

Remote Control Unit not working

Troubleshooting common problems with the wireless remote control unit.

Red light on Remote Control Unit not illuminating

Fixing issues related to the remote control's indicator light not illuminating.

Magnetic Contact Detector not working

Troubleshooting failures with magnetic contact detectors on doors or windows.

Red light on Magnetic Contact Detector not illuminating or is dim when door or window is opened

Addressing issues with the indicator light on magnetic contact detectors.

Magnetic Contact Detector false alarming

Steps to prevent false triggers from magnetic contact detectors.

Important Notice Following Alarm Installation

RE5000S Alarm Record

Extending Your RE5000S Professional Wireless Alarm System

Additional Solar Wireless Siren & Strobe RE5000SS

Information on adding a second siren for enhanced security coverage.

Dummy Siren & Strobe RE5000D

Using a non-functional unit as a visual deterrent to deter potential intruders.

Magnetic Contact Detector with Hard-wired Inputs RE5000MHW

A magnetic detector offering optional hard-wired input capabilities.

Medical Alert Pendant RE5000MP

A lightweight device for transmitting a medical alert signal to the control unit.

Wireless Smoke Detector RE5000SD

A smoke detector that signals fire events to the alarm system, providing high safety.

Security Dialler RE5000AD

A device connecting to the telephone line to automatically call for help during alarms.

Important Please Register Your Guarantee Within 14 Days of Purchase

Your Guarantee

Details the product warranty terms, conditions, and exclusions.

Guarantee Registration

For Free Entry Into Our Prize Draw

RE5000S Professional Solar Wireless Alarm System - Specification

Control Unit

Technical specifications for the main alarm control unit, including zones and features.

Wireless Passive Infra Red Detector

Technical specifications for the PIR motion sensor, including detection range and battery.

Magnetic Contact Detector (with hard-wired inputs)

Specifications for the door/window contact sensor, including wired input options.

Solar Wireless Siren & Strobe

Technical details for the external siren and strobe unit, including power and sound output.

Remote Control

Specifications for the wireless remote control unit, including buttons and battery.

Wireless Magnetic Contact Detector

Specifications for the standard magnetic contact detector, including operating gap.

Wireless Medical Pendant

Technical specifications for the medical alert pendant, including transmission and options.

Security Dialler

Specifications for the optional security dialler, including phone storage and trigger inputs.

Wireless Smoke Detector

Technical details for the wireless smoke detector, including its siren and communication.