Thermo Scientific
Revco
®
CxF -40C and -86C Chest Freezers
Operating Manual 7045808 Rev. 7
Visit us online to register your warranty
www.thermoscientific.com/labwarranty

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the REVCO ULT-390-10-A and is the answer not in the manual?

Summary

Installation and Start-up

Control Panel Keys, Display, Indicators

Describes control panel functions, keys, displays, and indicator lights.

Choose Location

Guidance on selecting a suitable and safe location for the freezer.

Remote Alarm Contacts and Analog Output

Explanation of remote alarm contacts and analog output connections.

Connect Unit to Electrical Power

Guidance on connecting the freezer to a grounded electrical outlet.

Freezer Start-Up

Steps for initial power-up and system configuration after installation.

Set Operating Temperature

Procedure for setting the desired operating temperature for the freezer.

Set High Temperature Alarm

How to configure the upper temperature limit for alarms.

Set Low Temperature Alarm

How to configure the lower temperature limit for alarms.

Calibrate

Calibrate Control Probe

Detailed steps for calibrating the main temperature control probe.

Configuration

High Alarm Test

Procedure to test the functionality of the high temperature alarm.

Low Alarm Test

Procedure to test the functionality of the low temperature alarm.

Alarms

High Stage System Failure Alarm (-86 C units only)

Describes the failure condition of the high stage compressor and fans.

Micro Board Failure Alarm

Indicates an internal communication failure with the micro board.

Lost Communication

Describes loss of communication between micro and display boards.

Er02 “CNT PRB FLT”

Control sensor failure, preventing proper temperature feedback.

Er03 “HSHX PRB FLT”

Heat exchange sensor failure for -86C units.

Er11 “COND PRB FLT”

Condenser probe sensor failure.

Maintenance

Defrost Chamber

Steps to safely defrost the freezer chamber.

Replace Battery(s)

Step-by-step guide for replacing the freezer's internal battery.

PREVENTIVE MAINTENANCE

Overview and schedule for routine preventive maintenance tasks.

Factory Installed Options

Back Up System (BUS) - P;N 1950533, 1950535

Details on the built-in backup system for maintaining temperature.

Set Optional BUS Set Point

Procedure to set the temperature set point for the backup system.

Test the BUS Operation

Steps to test the proper functioning of the BUS backup system.

Specifications

Refrigeration Schematics

Electrical Schematics

Electrical Schematic Model: 120 V 3 cu ft ULT Chest Freezer

Wiring diagram and switch settings for 120V 3 cu ft ULT Chest Freezer.

Electrical Schematic Model: 230 V, 50 & 60 Hz ULT Chest Freezer

Wiring diagram for 230V, 50 & 60 Hz ULT Chest Freezer.

Electrical Schematic Model: 230 V Chest Freezer

Wiring diagram and switch settings for 230V Chest Freezer.

Electrical Schematic Model: 120 V, 60 Hz ULT Chest Freezer

Wiring diagram for the 120V, 60 Hz ULT Chest Freezer.

Electrical Schematic Model: 120 V Chest Freezer

Wiring diagram and switch settings for 120V Chest Freezer.

Warranty Information

THERMO FISHER SCIENTIFIC FREEZER WARRANTY

Details the standard warranty terms and conditions for the freezer.

First Aid

REVCO ULT-390-10-A Specifications

General IconGeneral
BrandREVCO
ModelULT-390-10-A
CategoryLaboratory Equipment
LanguageEnglish