200W 200W 1600W 200W 1600W 900W
Safty notes
Installation of these products should only be undertaken by a qualied electrician.
The operational and electrical safety is only guaranteed, if the product is installed using its proper
accessories, in a position as specied in the installation instructions.
Any interference with the product makes the guarantee void.
If the time switch is mounted near equipment where heat produced raises the local ambient above 55°C. Then a space should be put
between the time switch and the equipment.
Function
The MicroRex D22 is a microprocessor controlled digital time switch. Eight programs of your choice can be stored and used to control the automatic operation of your electrical equipment. Each indi-
vidual weekday can have a separate program or you can have several days operating on the same Block program. To program the MicroRex D22 a picture is used and when this is complete the
chosen times are stored in the microprocessor memory. The MicroRex D22 makes available 2 separate switching channels. The summer-/winter changeover can be programmed for hand or automa-
tic operation.
State of output
= On
= Off
± 1h C
S OK
R
1
2
Hand switch
Channel 1
Channel 2
Choose function
Summer- / winter
changeover
Setting the hours, minutes,
days and channels
Delete
Fixing the hours, minutes,
days, channels and
continuous switching
Programming Buttons
1
2
1 2 3 4 5 6 7
Actual or On time
Weekday
Day number
Off time
Symbol for
Set actual time
Off days
Liquid Crystal Display
Technical data
Supply voltage: 230V 50/60Hz 120V 50/60Hz
Consumption: ca. 0,6W
Contact rating: 2 changeover contact 10A 250V~µ cos ϕ = 1
Parallel compensation: not allowed
Accuracy: ±2,5s/d
Terminal capacity: single strand multi strand
4 mm
2
2,5 mm
2
Program pictures: 8
Battery reserve: 100h
Storage ambient: -10°C to +60°C
Working ambient: -10°C to +55°C
Time switch
NT 29 17 87 02
MicroRex D22
S
OK
+
Presentation
Approximately 30 seconds after the supply voltage is connected the symbols
appear on the LCD.
Before any operations the complete memory must be reset.
2. Memory reset
1. Starting
This can only be done after a Reset.
Summer- / winter changeover can be made manually or automatically if set.
If manual changeover is required choose no during the date input. Automatic changeover
depends on your country / area. Choose the appropriate setting for your country / area.
3. Setting date and summer- / winter changeover
L
N
6
7
8
3
4 5
1 2
Connection
press both at
the same time
The time switch memory is completely clear.
Question and Answer IconNeed help?

Do you have a question about the REX MicroRex D22 and is the answer not in the manual?

Summary

MicroRex D22 Operation Guide

Introduction to MicroRex D22

Overview of the microprocessor controlled digital time switch and its programming.

Starting the Device

Initial display of symbols on LCD after supply voltage connection.

Memory Reset Procedure

How to perform a complete memory reset on the time switch.

Setting Date and Time

Procedure for setting the date and summer/winter changeover.

Setting Actual Time

Step-by-step guide to setting the correct current time.

Setting Switching Times

Instructions for programming ON and OFF times for programs.

7 Day Block Program

Programming for identical daily schedules over a 7-day period.

5 Day Monday to Friday Program

Programming for identical schedules from Monday to Friday.

Single Day Programs

Setting programs for individual days.

Checking Switching Times

How to verify programmed ON and OFF times.

Deleting Switching Times

Procedure to delete existing programs and set new ones.

Manual Operation

Controlling the device manually via ON/OFF states.

Continuous Switching

Setting the device for continuous ON or OFF operation.

Continuous Switching for Chosen Days

Programming continuous ON/OFF for a specific number of days.

Summer;Winter Changeover

Manual or automatic adjustment for daylight saving time.

Correcting Mistakes

How to correct errors during the programming mode.

Checking Date Setting

Verifying the date settings after input.

REX MicroRex D22 Specifications

General IconGeneral
TypeDigital Timer
Operating Voltage230 V AC
Shortest Switching Time1 minute
Frequency50/60 Hz
Maximum load3600 W
Timer channels1
Programs per channel8
DisplayLCD
MountingDIN rail
Switching Capacity16 A / 250 V AC