Rheem Classic
®
Series Two-Stage
Upflow/Horizontal Gas Furnaces
FORM NO. G11-514 REV. 1
RGPQ- Series
80% A.F.U.E.†
Models with Input Rates from
45-105 kBTU
(U.S. & Canadian Models)
A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with
Department of Energy test procedures.
The Rheem Classic
®
Series 2-Stage line of upflow/horizontal
gas furnaces are designed for utility rooms, closets, alcoves,
or attics. Because of the low-profile 34 inch [864 mm]
height, the upflow model can also be used to satisfy most
applications that traditionally call for a horizontal furnace.
The design is certified by CSA International.
Patented heat exchanger, constructed of aluminized steel for the
maximum in corrosion resistance and thermal fatigue reliability.
Low profile “34 inch” design is lighter and easier to handle,
and leaves room for optional equipment.
Convertible from upflow to horizontal left or right without field
conversion.
Left or right side gas and electric inlet connections with quick,
simple change.
Direct spark ignition models equipped with remote sense and
feature an integrated board with humidifier and electronic air
cleaner hookups.
Insulated blower compartment, a two stage gas valve and a
specially designed two speed draft inducer motor make it one
of the quietest furnaces on the market today.
Pre-paint galvanized steel cabinet.
Molded permanent filter.
Grab-holes in doors to aid in easy door removal and
replacement.
Compatible with single or two-stage thermostat. (For optimal
performance two-stage thermostat recommended.)
A variety of cooling coils and plenums designed to use with
Rheem Classic
®
Series 2-Stage gas furnaces are available as
optional accessories.
Furnaces can be installed in an upflow position or laid on
either side in a horizontal position. Field conversion not
required.
Air
Gas Furnaces
RGPQ Series
Annual Fuel Utilization Efficiency -
AFUE
THIS MODEL
ENER UIDE
97%78%
HIGH
MID
82% 88%
80.0%

Other manuals for Rheem 05EAUER

Questions and Answers

Summary

Equipment Details

Standard Equipment

Details on the completely assembled and wired standard components included with the furnace.

Optional Equipment

Details on optional accessories and components available for the furnace.

Model Features

Physical Data and Specifications

Model Number Identification

Upflow Dimensions

Horizontal Dimensions

Blower Performance Data

Accessories

Filter Racks and Return Air Cabinets

Information on external bottom filter racks, side return filter racks, and return air cabinets.

Fossil Fuel Kit

Details on the Fossil Fuel Kit (RXPF-F01 and F02) for use with Rheem Heat Pumps.

General Terms of Limited Warranty

Overview

The Rheem Classic® Series Two-Stage Upflow/Horizontal Gas Furnace (RGPQ- Series) is a heating appliance designed for residential use, suitable for utility rooms, closets, alcoves, or attics. Its low-profile 34-inch (864 mm) height allows it to be used in both upflow and horizontal configurations, eliminating the need for field conversion between these orientations. This design makes it versatile for various installation scenarios, including those traditionally requiring a horizontal furnace.

Function Description:

The RGPQ- Series furnace provides two-stage heating, meaning it can operate at a lower capacity for milder weather and a higher capacity for colder conditions. This two-stage operation, combined with a two-speed draft inducer motor and an insulated blower compartment, contributes to quieter operation and improved comfort. The furnace utilizes natural gas (or LP propane with an approved conversion kit) as its fuel source and is equipped with a direct spark ignition system for reliable startup. An integrated control board manages the furnace's operation, including blower control, safety limits, and includes hookups for a humidifier and electronic air cleaner.

Important Technical Specifications:

  • AFUE (Annual Fuel Utilization Efficiency): 80%
  • Input Rates: 45-105 KBTU (U.S. & Canadian Models)
  • Height: 34 inches (864 mm)
  • Gas Connection Size: 1/2 inch (12.7 mm) N.P.T.
  • Electrical: 115V, 60HZ, 1Ø
  • Heat Exchanger: Patented, constructed of aluminized steel for corrosion resistance and thermal fatigue reliability.
  • Blower Motor: Direct drive multi-speed PSC motor (available in 1/2 HP, 3/4 HP depending on model).
  • Cooling CFM Range: 1100-2100 CFM (519-991 L/s) depending on model and speed.
  • Temperature Rise Range (High Input): 25-80°F (13.9-44.4°C) depending on model.
  • Temperature Rise Range (Low Input): 15-70°F (8.3-38.9°C) depending on model.
  • Max. Outlet Air Temperature: 155-190°F (68.3-87.7°C) depending on model.
  • Standard Filter Size: 15¾ x 25 inches (400 x 635 mm) (filters shipped with furnace or suitable 1" filter).
  • Shipping Weight: 85-150 lbs (39-68 kg) depending on model.
  • Clearances to Combustible Material (Upflow/Horizontal):
    • Left/Right Side: 0-4 inches (0-102 mm)
    • Back: 0 inches (0 mm)
    • Top: 1 inch (25 mm)
    • Front: 3 inches (76 mm)
    • Vent: 6 inches (152 mm) (may be 1 inch (25 mm) with type B vent).
    • Note: Furnaces must be vented in accordance with National Fuel Gas Code, ANSI Z223.1 and/or Can/CGA-B149 Installation Codes and local codes.

Usage Features:

  • Two-Stage Operation: Provides enhanced comfort and efficiency by adjusting heating output based on demand.
  • Upflow/Horizontal Versatility: Can be installed in either upflow or horizontal positions without field conversion, offering flexible installation options.
  • Quiet Operation: Insulated blower compartment, two-stage gas valve, and two-speed draft inducer motor contribute to a quieter heating experience.
  • Easy Access: Grab-holes in the doors facilitate easy removal and replacement for maintenance or service.
  • Thermostat Compatibility: Compatible with both single and two-stage thermostats, with two-stage thermostats recommended for optimal performance.
  • Integrated Control Board: Features hookups for humidifiers and electronic air cleaners, simplifying integration with other HVAC accessories.
  • Gas and Electric Inlet Connections: Left or right side connections with quick, simple change for installation flexibility.
  • Optional Accessories: A variety of cooling coils, plenums, and return air cabinets are available to complement the furnace. Fossil fuel kits (RXPF-F01 and F02) are available for use with Rheem Heat Pumps.
  • High Altitude Derate: Specific procedures for high altitude derate are outlined in the furnace installation instructions (for Canada) or Conversion Kit Index Form (for U.S.).

Maintenance Features:

  • Molded Permanent Filter: Included for air filtration.
  • Easy Service Access: The design allows for straightforward access to internal components for servicing.
  • Flame Sensor Diagnostics: Aids in troubleshooting and maintenance.
  • Fused Protection (Secondary): Provides electrical protection for the furnace.
  • Durable Construction: Pre-paint galvanized steel cabinet and aluminized steel heat exchanger are designed for longevity and resistance to corrosion.

Important Warnings:

  • This furnace is not approved or recommended for use in mobile homes.
  • A solid metal base plate must be in place when the furnace is installed with side air return ducts to prevent combustion products from circulating into the living space.
  • The RXGR-C24B return air cabinet must only be installed on the side opposite the gas and electrical connections.
  • This furnace is not approved or recommended for installation on its back, with access doors facing upwards.