COMMISSIONING
24
The modes are:
Standby mode – water is hot
Call for heating received – system checks performed
Note: if call for heating received, unit may wait and
continue flashing until five minutes has elapsed after its
last operation and until the compressor has cooled
Circulator commences circulation
Heat pump operation – compressor and fan running
No power at the water heater or to the heat pump or a
possible fault condition
Refer to notes overleaf before calling for service
Ambient temperature < 0°C Heating unit on
Storage tank thermistor fault condition Heating unit on
Heat exchanger (heat pump) water outlet > 80°C
Heating unit on
Evaporator < -3°C Heating unit on
Refrigeration system fault 1 Heating unit on
Refrigeration system fault 2 Heating unit on
Water flow fault Heating unit on
Compressor over temperature condition (> 110°C)
Heating unit on
Heating stopped due to insufficient flow rate
Heating unit off
Heat exchanger (heat pump) water outlet thermistor
fault condition Heating unit on
Heat exchanger (heat pump) water inlet thermistor fault
condition Heating unit on
Evaporator thermistor fault condition Heating unit on
Compressor thermistor fault condition Heating unit on
Ambient temperature thermistor fault condition
Heating unit on