9
Forced Air Inlet
4' (1.2 m)
Minimum
3' (0.9 m)
Minimum
10' (3 m)
Minimum
1' (0.3 m)
Minimum
4' (1.2 m)
Minimum
4' (1.2 m)
Minimum
Figure 4. Clearances
Pagoda Top Installation
1. Insert tabs into keyhole (4 places). See Figure 5,
detail A.
2. Snap tabs into keyholes so as not to pull out. See
Figure 5, detail B.
OUTDOOR TOP
(SHIPPED LOOSE WITH HEATER)
DETAIL A DETAIL B
Figure 5. Outdoor Top Installation
For installations in Florida and Texas, that must
comply with the Florida or Texas Building Code, follow
the directions shown in Figure 7 for the installation of
hurricane tie-down brackets for all models.
Indoor Heater Installation
The heater is also design-certied for indoor installation
when equipped with the approved drafthood.
For Canada, indoor installation is restricted to an enclosure
that is not occupied and does not directly communicate
with an occupied area. Refer to the latest edition of CAN/
CSA-B149 for specic requirements. Locate heater as
close as is practical to a chimney or gas vent. Heater
must always be vented to the outside. See section "Vent
Piping" on page 13 for details. Minimum allowable
space is shown on the nameplate.
AA
WARNING: Indoor heaters require a drafthood that
must be connected to a vent pipe and properly vented to
the outside. Failure to follow this procedure can cause
re or fatal carbon monoxide poisoning.
Outdoor and Indoor Stacks
The outdoor and indoor stacks are optional equipment
and do not come standard with the heater. Refer to
installation instructions inside box for instructions on
how to install outdoor/indoor stack.
Outdoor Stack Indoor Stack
Model Part No Part No.
207A 009834 009838
267A 009835 009839
337A 009836 009840
407A 009837 009841
Table D. Outdoor and Indoor Stack Kit Number
OUTDOOR STACK KIT
(1) Outdoor stack, painted
(1) Adapter plate
(3) Mounting brackets (clips)
(1) Top panel cover
(2) 1-foot sections of metal tape
(3) Screws
(1) Instructions
Clips
Figure 6. Outdoor Stack Kit Components
NOTE: The outdoor drafthood kit does not require any
additional vent pipe for proper operation. This drafthood
functions as the vent termination.