FIGURE 75b
MENU TREE CONTINUED
6. FURN HI PR SW Indicates the
state of the High Pressure Control
(HPC) (also known as high pres-
sure switch) – either OPEN or
CLOSED.
7. GAS VLV PRCNT
Indicates the
firing rate of the modulating gas
valve. This value can be any num-
ber between 40% and 100%
depending on the thermostat
demand.
8. GAS VLV RELAY
Indicates the
state of the gas valve relay –either
ON or OFF. ON indicates that the
4. IDM OUTPUT
Indicates the state
of the Induced Draft Motor (IDM) –
OFF, HI or LO. The indication is
the state at which the furnace con-
trol expects the motor to be. If the
indication is HI or LO and the motor
is not turning, a number of prob-
lems could be the cause – including
a non-functioning blower relay on
the furnace control or a non func-
tioning inducer.
5. FURN LO PR SW
Indicates the
state of the Low Pressure Control
(LPC) (also known as low pressure
switch) – either OPEN or CLOSED.
main gas valve solenoid is
engaged. Any time the indica-
tion is ON, flame should be pre-
sent.
9. FLAME
Indicates the pres-
ence of a flame. The possibili-
ties are “OFF”, “MARGINAL”,
“GOOD” and “UNEXPECTED”.
A marginal flame can be an indi-
cator that the flame sense rod
needs to be cleaned. “UNEX-
PECTED” flame is a serious
condition and must be dealt with
immediately by a professional,
licensed HVAC technician.
MOD HT HRS
MOD HT CYCLS
TOTAL DAYS PWRD
BLOWER HRS
BLOWER CYCLES
NOTE: There may be a
delay of several seconds
when accessing user
menus or submenus.
This is normal.