EasyManua.ls Logo

Rheem RGPS series User Manual

Rheem RGPS series
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Rheem Value Series
Upflow/Horizontal Gas Furnace
FORM NO. G11-520 REV. 1
RGPS- Series
80% A.F.U.E.†
Input Rates 50-150 kBTU
The Rheem Value Series line of upflow/horizontal gas
furnaces are designed for utility rooms, closets, alcoves,
or attics. Because of the model’s low-profile 34 inch
[864 mm] height, the upflow model can also be used to
satisfy most applications that traditionally call for a
horizontal furnace.
The design is certified by CSA International.
Unique solid door design leads to quiet operation.
Patented heat exchanger, constructed of aluminized steel for the
maximum in corrosion resistance and thermal fatigue reliability.
Low profile “34 inch” [864 mm] design is lighter and easier to
handle, and leaves room for optional equipment.
Convertible from upflow to horizontal left or right without field
conversion.
Left or right side gas and electric inlet connections allow
quick and simple change.
Direct spark ignition with remote sense, features a integrated
board with an electronic air cleaner hookup.
Prepaint galvanized steel cabinet.
A slow-open gas valve and a specially designed draft inducer
motor make it one of the quietest furnaces on the market
today.
Grab-holes in doors to aid in easy door removal and
replacement.
A variety of cooling coils and plenums designed to use with
Rheem Value Series gas furnaces are available as optional
accessories.
Air
Gas Furnaces
RGPS Series
Annual Fuel Utilization Efficiency -
AFUE
THIS MODEL
ENER UIDE
97%78%
HIGH
MID
82% 88%
80.0%
A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with
Department of Energy test procedures.
Question and Answer IconNeed help?

Do you have a question about the Rheem RGPS series and is the answer not in the manual?

Rheem RGPS series Specifications

General IconGeneral
BrandRheem
ModelRGPS series
CategoryFurnace
LanguageEnglish

Summary

Standard & Optional Equipment

STANDARD EQUIPMENT

Lists completely assembled components: induced draft, pressure switch, controls, motor, and safety features.

OPTIONAL EQUIPMENT

Details optional accessories like Twinning Kit and filter frames, noting fuel limitations.

Model Features and Specifications

Model Features

Highlights design certifications, quiet operation, patented heat exchanger, and low-profile 34-inch design.

Physical Data and Specifications

Presents technical data: input/output rates, dimensions, weights, and clearances for various RGPS models.

Model Number Identification

RGPS Series Model Nomenclature

Explains the coding system for Rheem RGPS Series gas furnace models, detailing series, capacity, and features.

Dimensional Data

Upflow Application Dimensions

Provides physical dimensions, connection sizes, and clearance requirements for upflow installations of RGPS furnaces.

Dimensional Data for Horizontal Application

Horizontal Application Dimensions

Details physical dimensions, connection sizes, and clearance requirements for horizontal installations of RGPS furnaces.

Blower Performance Data

CFM Air Delivery vs. Static Pressure

Presents blower performance data, showing CFM delivery at various static pressures for different blower speeds and models.

Accessories

Filter Racks and Return Air Cabinets

Details internal and side/bottom return air filter racks and cabinets, specifying sizes and filter compatibility.

Fuel Kits and Twinning Kits

Lists optional fossil fuel conversion kits and twinning kits for furnaces, specifying their purpose.

High Altitude Installation Notes

Provides guidance and warnings for high altitude installations, including orifice recalculation and derating for Canadian models.

Limited Warranty Information

General Terms of Limited Warranty

Outlines Rheem's policy for furnishing replacement parts for failing components within specified warranty periods.