- (02 - 10) -
OUTDOOR UNIT
ROSH18-36A
OUTDOOR UNIT
ROSH18-36A
6. ADDITIONAL CHARGE CALCULATION
MODEL : ROSH18ASJ, ROSH24ASJ
z
REFRIGERANT CHARGE
MODEL : ROSH30AXJ, ROSH36AXJ
z
REFRIGERANT CHARGE
Refrigerant type R410A
Refrigerant amount
lbs. oz. 3lbs. 1oz.
g 1400
Total pipe length
ft. 49 or less 66 (MAX)
0.22oz./ft.
(20g/m)
m 15 or less 20 (MAX)
Additional charge
oz. 0 3.5
g 0 100
Refrigerant type R410A
Refrigerant amount
lbs. oz. 4lbs. 10.1oz.
g 2100
Total pipe length
ft. 66 or less 98 131 164
0.43oz./ft.
(40g/m)
m 20 or less 30 40 50 (MAX)
Additional charge
oz. 0 14.1 28.2 42.3
g 0 400 800 1200