EasyManua.ls Logo

Rheem RTGH-RH10DV - Page 75

Rheem RTGH-RH10DV
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AP18733 REV. 3.2.17
75
Figure 54 – Flame Sight Glass
DHW Inlet Temperature Sensor (7850P-015) Exhaust Temperature
Sensor (7850P-070)
Temperature (°F/ °C) Resistance (Ω)
Resistance (Ω)
-4 / -20 28409
5 / -15 22152
14 / -10 17408
23 / -5 13782
32 / 0 10990
41 / 5 8824
50 / 10 7131
59 / 15 5800
68 / 20 4747
77 / 25 3906
86 / 30 3233
95 / 35 2690
104 / 40 2250
113 / 45 1891
122 / 50 1598
131 / 55 1356
140 / 60 1155
149 / 65 989
158 / 70 850
167 / 75 733
176 / 80 635
185 / 85 552
194 / 90 482
203 / 95 421
212 / 100 370
DHW Inlet Temperature Sensor (7850P-015) Exhaust Temperature
Sensor (7850P-070)
Temperature (°F/ °C) Resistance (Ω)
Resistance (Ω)
-4 / -20 62162
5 / -15 48440
14 / -10 38045
23 / -5 30107
32 / 0 23998
41 / 5 19261
50 / 10 15562
59 / 15 12655
68 / 20 10353
77 / 25 8520
86 / 30 7051
95 / 35 5867
104 / 40 4908
113 / 45 4125
122 / 50 3485
131 / 55 2957
140 / 60 2520
149 / 65 2157
158 / 70 1854
167 / 75 1600
176 / 80 1386
185 / 85 1205
194 / 90 1051
203 / 95 920
212 / 100 808
Visual check Port
Port should show
blue flame.