EasyManua.ls Logo

RIB JOLLY ONE - JOLLY ONE Technical Specifications; Technical Data Summary; Rolling Gate Control Safety

RIB JOLLY ONE
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
24
G
B
TECHNICAL DATA / INSTALLATION JOLLY ONE
Measurements in mm/in
1 - JOLLY ONE operator
2 - Photoelectric cells (external)
3 - Push-Button
4 - Key selector
5 - Tuned aerial
6 - Flashing lamp
IN ORDER TO ENSURE A CORRECT FUNCTION ONLY RIB’S COMPONENTS
MUST BE USED
373,5 / 14,7
Ø 60 / 2,36
Ø 205 / 8,07
TECHNICAL DATA
JOLLY ONE
Max gate weight kg/lbs 220/485
Max gate surface m
2
16
Limit switch winding capacity N. rotat. 8,5
Nominal functioning torque Nm 150
Max operating torque Nm 110
Max lifting force from earth kg/lbs 150/330
Max operating force kg/lbs 110/242
Pulley revolutions rpm 10,4 (50Hz) - 13,4 (60Hz)
Pulley diameter mm/in 200/7,9 - 220/8,67 with adapter ACJ9055
Shaft diameter mm/in 60/2,3 - 42/1,64 with adapter ACJ9040 - 48/1,9 with adapter ACJ9050
EEC Power supply 230V ~ 50-60Hz
Motor capacity with load W 570 (50Hz) - 550 (60Hz)
Power absorbed with load A 2,7 (50Hz) - 2,6 (60Hz)
Capacitor µF 20
Functioning cycles N. 5 - 20s/2s
Daily operations suggested N. 20
Service 30%
Nominal functioning time s 240
Motor weight kg/lbs 9,5
Working Temperature °C -10 ÷ +55
Protection IP 30
ROLLING GATE CONTROL
The European Standard EN 12604 “Industrial, Commercial and Garage Doors and Gates -
Mechanical Aspects - Requirements”, at the point 4.3. “Protection against unintentional and
uncontrolled movements” requires also that*:
a - The vertically operating door leaves shall be balanced so that the door leaf can stop in
any position, or that the out-of-balance state shall not produce, in any case, a static
force at the primary closing edge of the door exceeding 150N (15,3 kg / 33,70 lbs).
Verify it after having manually released the JOLLY ONE operator.
b - If a spring fails, the resulting out-of-balance static force occurring at the primary
closing edge of the roller shutter shall not exceed 200N (20,4 kg / 44,94 lbs), even
when the Jolly operator is manually released. After this failure, you must intervene on
the door to substitute the broken spring and correct the balance state. Therefore, we
suggest you to fraction the roller shutter weight with an adequate number of springs
(* This is a free interpretation).
WARNING: The EN 12453 standard “Industrial, commercial and garage doors and gates
- safety in use of power operated doors - test methods” at point 6.2.2 “safeguarding
against hazard of being lifted” provides that the rolling gate shall not be able to lift more
than 20 kg / 44 lbs. In order to meet this standard,
RIB suggests to install the control
board with electric power regulation J-CRX (cod. ABJ7080).
Parts to install according to EN 12453 standard
COMMAND TYPE
USE OF THE SHUTTER
Skilled persons
(out of public area*)
Skilled persons
(public area)
Not skilled
persons
Hold-to-run operation A B Not possible
Impulsive - in sight
(e.g. push-button)
C or E C or E C and D, or E
impulsive - out of sight
(e.g. remote)
C or E C and D, or E C and D, or E
automatic C and D, or E C and D, or E C and D, or E
* a typical example are those doors which do not have access to any public way
A: Hold-to-run operation made by push-button ex: code ACG2013
B: Hold-to-run operation made by key selector ex: code ACG1010
C: Adjustable power of the motor or photocells to respect impact forces as indicated in
Annex A
D: Safety strips and/or other additional devices to reduce the probability of contact with
the door.
E: Devices installed in such a way that a person can not be touched by the door.